User`s manual

2-11
Setting the Operating and System Conditions
2
[9] PC monitor screen
Specify whether to display the PC monitor
on the operation screen.
Select the "
PC-MNTR" line on the "TYPE
RUN COND" screen and select "YES" on
the popup menu. Now the PC monitor
screen can be displayed.
Select "SCREEN-CHG" on the lower menu
bar of the operation screen and then select
"PC-MNTR" on the popup menu. The PC
monitor will be displayed.
[10] Through display
Select the desired measurement image status
(FREEZE or THROUGH) by chosing either "YES" or
"NO" on the operation screen.
 READY2
3
1
X00∼ 07
Y000∼007
C000∼007
4
5
6
7
OK
(TYPE00)AREA1
T C1 DRK
LOCK FULL V*.**
C1=002.2 OK
C2=100.0 OK
MEAS
XXXXms 2001-10-14 10:38
[NUMERIC CALC] [TMR] [CNTR]
AN00= +00000250.0 OK TM0:200 CN0:100
AN01= -00000300.0 OK TM1:300 CN1:150
AN02=NOT SET TM2:NOT SET CN2:NOT SET
AN03=NOT SET TM3:NOT SET CN3:NOT SET
AN04=NOT SET TM4:NOT SET CN4:NOT SET
AN05=NOT SET TM5:NOT SET CN5:NOT SET
AN06=NOT SET TM6:NOTSET CN6:NOT SET
AN07=NOT SET TM7:NOT SET CN7:NOT SET
MMU-CHG MAIN-COND SEL-OUT SEL-AUX SEL-NUM SCREEN-CHG CHG-TYPE
NO
YES
Description
THROUGH DISPLAY
Measurements can be
made on a through image.
Measurements can be
made on a frozen image.
1
MONITOR OUTPUT CAM1
2
CAPTURE IMG PARTIAL-IMG
3
MESSAGE DISPLAY YES(NUMERIC)
4
PATTERN DISPLAY YES
5
SHOW BINARY IMG YES
6
SHOW
θ
FIX IMG YES
7
OPS MAIN DISP YES
8
DISP CHG-EVAL NO
9
PC-MNTR NO
0
THROUGH DISPLAY NO
q
EXTENSION FUNC. NO
TYPE RUN COND SCREEN SAVE F C1 BRT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
YES
NO
Menu bar
SEL-OUT
Description
Change the output relay address (Y00 to Y15) using the up and down keys
(in units of 8 points).
SEL-AUX
Change the auxiliary relay address (C000 to C127) using the up and down
keys (in units of 8 points).
SEL-NUM
Change the final numerical calculation address (AN00 to AN15) using the
up and down keys (in units of 8 points).
The other data displayed is the same as on the operation screen. -See page 1-10.
1 The ON (
) or OFF () status of the input relays (X00 to X07) is displayed.
2 The ON (
) or OFF () status of the output relays (Y00 to Y15) is displayed.
3 The ON (
) or OFF () status of the auxiliary relays (C000 to C127) is displayed.
4 The results (AN00 to AN15) of the final numerical calculations are displayed.
5 The current timer value is displayed.
6The current counter value is displayed.
7 Menu bar