User`s manual

2-12
Setting the Operating and System Conditions
2
[11] Extension functions
The extension function has crosshair cursor display and manual display functions.
(1) Crosshair cursor display
The crosshair cursor can be displayed on any position.
- "1" equals a 16-pixel line. "2" equals a full line.
- The initial coordinates of the crosshair cursor center are (256,240)
Operation procedure
1. On the "TYPE RUN COND" screen,
move the cursor to item
" EXTENSION FUNC." using the
up and down keys, and press the
SET key.
2. Select "DISPLAY+CURSOR" on the
popup menu and press the SET
key.
3. Press the SET key on the
" DISPLAY+CURSOR 1" line and
select "1" or "2" on the popup menu.
Then press the SET key.
4. Select " CROSS CURSOR
COORD" and press the SET key.
Now, the crosshair appear on the
screen. Move the crosshair cursor
using the up/down/left/right arrow
keys. (It moves one pixel at a time)
5. When the cursor is positioned
where you want it, press the SET
key to confirm the position.
If you select " DISPLAY+CURSOR 2," you
can display two cursors when you output monitor
images from Cameras 1 and 2.
NO
DISPLAY+CURSOR
MANL-MEAS
1
MONITOR OUTPUT CAM1
2
CAPTURE IMG PARTIAL-IMG
3
MESSAGE DISPLAY YES(NUMERIC)
4
PATTERN DISPLAY YES
5
SHOW BINARY IMG YES
6
SHOW
θ
FIX IMG YES
7
OPS MAIN DISP YES
8
DISP CHG-EVAL NO
9
PC-MNTR NO
0
THROUGH DISPLAY NO
q
EXTENSION FUNC. DISPLAY+CURSOR
w
DISPLAY+CURSOR 1
1
e
CLOSS CURSOR COORD SET
(256,240)
r
DISPLAY+CURSOR 2 NO
1
2
TYPE RUN COND SCREEN SAVE
F C1 BRT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
OK
X0∼7 Y0∼7 READY
(TYPE00)AREA1
MEAS
XXXX
ms
2002-10-14 10:38
MEASURE 0 CAM1 POSI DEVIATION
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
[Display example]
Measurement image of
camera 1.
Measurement image of
camera 2.
Displays two crosshair cursors.