User`s manual

2-13
Setting the Operating and System Conditions
2
(2) Manual measurement
With this function, you can measure distance between two points, the distance between X
coordinates, or the distance between Y coordinates that were selected manually on the operation
main screen.
Operation procedure
1. Select " EXTENSION FUNC." on the
"TYPE RUN COND" menu using the up
and down arrow keys. Then press the SET
key.
2. Select "MANL-MEAS" on the popup menu
and press the SET key.
3. Move the cursor to the upper function menu
by pressing the TRG/BRT key and select
"SCREEN." Then press the SET key.
Select "OPS-MENU" on the popup menu
and return to the operation screen.
4. Move the cursor to the "MNU-CHG"
(menu change) item on the bottom
of the operation screen and press
the SET key to change the bottom
menu display. Move the cursor to
"MANL-MEAS" (manual
measurement) and press the SET
key.
5. The menu items for manual
measurements will appear on the
screen.
6. Select " CURSOR1-COORD" or "
CURSOR2-COORD" and press
the SET key.
7. Move cursor 1 or cursor 2 using the
up/down/left/right keys. (They move
one pixel at a time.)
The distance between the two
points, and between the X
coordinates and Y coordinates for
the two points, will change on real
time basis.
8. After the positions of the points are determined, press the SET key.
9. When the operation is complete, press the ESC key.
The manual measurement menu items will disappear.
1
MONITOR OUTPUT CAM1
2
CAPTURE IMG PARTIAL-IMG
3
MESSAGE DISPLAY YES(NUMERIC)
4
PATTERN DISPLAY YES
5
SHOW BINARY IMG YES
6
SHOW
θ
FIX IMG YES
7
OPS MAIN DISP YES
8
DISP CHG-EVAL NO
9
PC-MNTR NO
0
THROUGH DISPLAY NO
q
EXTENSION FUNC. MANL-MEAS
TYPE RUN COND SCREEN SAVE F C1 BRT
NO
DISPLAY+CURSOR
MANL-MEAS
1
MONITOR OUTPUT CAM1
2
CAPTURE IMG PARTIAL-IMG
3
MESSAGE DISPLAY YES(NUMERIC)
4
PATTERN DISPLAY YES
5
SHOW BINARY IMG YES
6
SHOW
θ
FIX IMG YES
7
OPS MAIN DISP YES
8
DISP CHG-EVAL NO
9
PC-MNTR NO
0
THROUGH DISPLAY NO
q
EXTENSION FUNC. NO
TYPE RUN COND SCREEN SAVE F C1 BRT
OPS-MENU
MAIN
SELECT
RETURN
OK
X0∼7 Y0∼7 READY
(TYPE00)AREA1
MEAS
XXXX
ms
2002-10-14 10:38
MEASURE 0 CAM1 POSI DEVIATION
MANL-MEAS
1
CURSOR1-COORD MOVE(224,208)
2
CURSOR2-COORD MOVE(287,271)
DIST-BETW-2PT 089.0
DIST-BETW-X 063.0
DEST-BETW-Y 063.0
MNU-CHG NEXT-NG CHG-C1 CHG-C2 MANL-MEAS SHORTCUT
Cross hair cursor 1 Cross hair cursor 2
Manual measurement
menu