User`s manual

Setting the Conditions for Each Object Type
3-19
3
Setting method
There are two ways to get to the evaluation condition setting screen.
1) Select "CND" in the upper function menu on
the MEAS CND (or REG COND) screen and
press the SET key. Select "EVALUATION" on
the pop up menu to go to the"EVALUAT
COND" screen.
2) Move the cursor to the "EVALUATION COND"
item on the Menu tree screen and press the
SET key.
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0(POSI-DEVIATION)
IMG PRE-PROC
MEAS CND
REG-COND(S)
REG-COND(E)
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
POSI-CORRECT
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM.CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
+
+
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
1
REGISTER NO.
2
CONDITION SET
3
X COORD. (BDL0)
4
Y COORD. (MDL0)
5
x DEVIATE (MDL0)
6
y DEVIATE (MDL0)
7
MATCH LVL (MDL0)
8
ANGULAR DEVIATE
9
X COORD. (MDL1)
0
Y COORD. (MDL1)
q
x DEVIATE (MDL1)
w
y DEVIATE (MDL1)
e
MATCH LVL (MDL1)
r
TEST
SELECT OBJECT TYPE COND
F C1 BRT
15141312111009080706050403020100
S
×
MEAS CND SCREEN COND SAVE
F C1 BRT
1
DTECT PRECISION STANDARD
2
REGISTER NO. 0(0~7)
3
MODE 1P-SCH
4
DTECT ANGL –15¡
5
ANGLE UNIT 10
REGISTER NO.
6
MDL 0
7
MDL 1
IMG PRE-PROC
REG-COND(S)
REG-COND(E)
POSITION CORRECTION
EVALUATION
DST&ANGL
NUM-CALC
OUT
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC