User`s manual

Setting the Conditions for Each Object Type
3-35
3
3-3 Input & Output / System settings
[1] Illuminance (light level) monitor
(1) Purpose
1. Allows the system to monitor changes the lighting of the environment
If the light level exceeds the preset lighting range, it will be regarded as a change in the
environment and "OVR ILLM RANGE" will be displayed on the MAIN OPS MENU.
2. Automatic adjustment of the threshold values used for binary conversions can follow
changes in the lighting environment.
The threshold value is modified from the user's setting due to changes in the actual brightness
measured in the environment.
(2) Applications
Used when the level of illumination changed due to changes in voltage or when the influence of
sunlight in the workplace cannot be ignored.
(3) Setting procedure
Select "OBJECT TYPE COND" "TYPE00" (current type) and "OBJ-TYPE SYS," in that order, on
the "MAIN MENU" screen.
1. Select " MNTR LIGHT LVL (CAM1)" (monitor
light level). Select "YES" from the popup menu.
Then, the " LIGHT LV COND" item will
appear on the screen.
2. Select " LIGHT LV COND" and press the SET
key. The "LIGHT LV COND" screen and
monitoring window will appear.
3. Press the SEL key and move the cursor to the
upper function menu. Set the image mode to
"T" (Through).
1
REGST NG IMG YES
2
HALT ON NG MEAS YES
3
MNTR LIGHT LVL(CAM1) YES
4
LIGHT LV COND (TO NEXT SUB-BENU)
5
MNTR LIGHT LVL(CAM2) YES
6
LIGHT LV COND (TO NEXT SUB-MENU)
7
MOVE ALL WINDOW (TO NEXT SUB-MENU)
NO
YES
OBJ-TYPE SYS. SCREEN SAVE
F C1 BRT
Displayed when
the controller is
the IV-S32MX
/S33M.
LIGHT LV COND SCREEN SAVE F C1 BRT
1
SIZE Y08(4~32)X08(4~65)
2
POSITION (248,232)
3
THRESHOLD VALUE U.LM255 L.LM000(0~255)
MEAS.AVG.GRA=000.0
4
REG AVG.GRAY LV EXEC REG.AVG.GRAY=000.0
SEL=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
Monitor window