User`s manual

17-11
Communication (General Purpose Serial Interface)
17
(5) Illuminance level reading: code 28(H)
The illuminance level measured by the illuminance monitor function and the evaluation result are
read.
- Camera No. 0: camera 1, 1: camera 2
- Object type Object type for which the measurement was executed: 00 to 3F
- Result 0: NG, 1: OK
- Illuminance 000.0 to 255.0
Ë Response
:28
RC
(H)
RC
(L)
Illuminance
10
2
10
1
10
0
10
-1
SC
(H)
SC
(L)
CR
Result
:28
SC
(H)
SC
(L)
Ë Command
CR
Object
type
Station
No.
Station
No.
Execution
camera
(6) Corrected light level reading: code 29(H)
The corrected light level measured by the illuminance monitor function, the evaluation result and
preset reference light level are read.
- Object type Object type for which the measurement was executed: 00 to 3F
- Result 0: NG, 1: OK
- Corrected light level Corrected light level (0 to 255.0)
- Reference light level Light level used as the criterion (0 to 255.0)
Ë Response
:29RC
(H)
RC
(L)
Corrected
light level
Reference
light level
± 10
2
10
1
10
0
10
2
10
1
10
0
10
-1
10
-1
SC
(H)
SC
(L)
CR
Result
:29SC
(H)
SC
(L)
Ë
Command
CR
Object
type
Station
No.
Station
No.
Execution
camera
- Camera No. 0: camera 1, 1: camera 2