User`s manual

Setting Measurement Conditions
3-4
3
Positional deviation measurement (gray scale search), degree
of match inspection, lead inspection, multiple position
measurement (gray scale search), and multiple degree of match
inspection.
Area measurement by binary conversion, object counting by
binary conversion, object identification by binary conversion.
Positional deviation measurement (gray scale search), degree
of match inspection, lead inspection (criteria search), multiple
position measurement (gray scale search) and multiple degree
of match inspection.
Positional deviation measurement (edge detection), multiple
position measurement (edge detection).
Area measurement by binary conversion, object counting by
binary conversion, object identification by binary conversion.
Line type
Solid lines
Dotted lines
Measurement programs
Image processing used
Reference image for gray
scale search and binary
image matching
Window containing a
binary image
Gray scale search area
detection
Edge of an area detection
Binary image window
mask
REG COND SCREEN COND SAVE DETAIL
F C1 BRT
RECTANGLE
X-LINE
Y-LINE
1
REGISTER NO 0(0~7)
2
MEAS SHAPE (MDL0) RECTANGLE
3
REFIMG ARE (MDL0) SET (224,208)~(287,271)
4
SEARCH ARE (MDL0) SET (216,200)~(295,279)
EX: Register conditions of "Positional deviation
measurement."
3-2 Shared settings
[1] Window shape selection and settings
This section describes how to select and set the
window shapes used for image processing (e.g.
rectangular windows, horizontal or vertical line
boundaries, circle windows, elliptical windows, and
polygonal windows). This can be done using the up,
down, left, and right setting keys on the remote key
pad.
(1) Rectangular window