13-3
Specifications
13
Data memory
13-3
JW-32CUM1 performance specifications and communication specifications
Shown below are the performance specifications and communication specifications for the JW-
32CUM1 control module.
[1] Performance specification
Shown below are the performance specifications for the JW-32CUM1.
Stored program system
Compatible cyclic calculation and interrupt dealing system
Basic instruction (except OUT, TMR, CNT, MD) : 0.038 µs/instruction.
OUT instruction : 0.076 µs/instruction
Application instructions, TMR, CNT, MD instructions : average number µ to
several tens µs/instruction
Basic instruction : 20 Application instruction : 177
15.5K words/31.5K words (switchover)
By built-in lithium battery. (Available for ROM operation using integrated flash ROM.)
Both block refresh system and refresh system by instruction are applied.
Max.1024 points
Max. rack panels : 8 rack panels *1
30720 points 00000 to 15777 コ0000 to コ1577
20000 to 75777 コ2000 to コ7577
2560 points (10000 to 14777) [コ1000 to コ1477]
448 points (15000 to 15677) [コ1500 to コ1567]
64 points (15700 to 15777) [コ1570 to コ1577]
2048 points (20000 to 23777) [コ2000 to コ2377] *2
4096 points (30000 to 37777) [コ3000 to コ3777]
1024 points (40000 to 41777) [コ4000 to コ4177]
64 points (07300 to 07377)
07300 to 07337 : Reserved area 07366 : Normally OFF contact
07340 to 07347 :
Error code strage
07370 : Memory error
07354 : Non-carry flag 07371: CPU error
07355 : Error flag 07372 : Battery error
07356 : Carry flag 07373 : I/O error
07357 : Zero flag 07374 : Option error
07360 :
0.1 second clock
07375 : Special I/O error
07362 : Initialize pulse 07376 : Expansion power supply error
07363 : Fuse blown 07377 : Power supply error
07364 : 1.0 second clock
07365 : Setting value change switch
Program system
Control system
Processing speed
Type and numbers of
instruction
Program size
Memory back-up
I/O control system
Max. numbers of
I/O points
Relay
Relay for option
module
Flag for option
module
Flag for I/O link
Relay for I/O link
Relay for special I/O
module (basic system)
Relay for special
I/O module (Remote
I/O slave station)
Special relay
Items
Specifications
*1 In case of using I/O bus expansion adapter JW-31EA/32EA.