User`s manual
Directions for use
7-6
7
[2] I/O relays allocated to each module
Relay numbers in each rack panel are automatically allocated in series following each rack top address
set by I/O register. Number of points and contents of relays allocated varies with kinds of module.
Kinds of
module
Allocation No.
of points
Contents of allocated relay No.
8 points
input/output
16
Instead of 8 points, 16 points are assigned.
- The first half 8 points is acceptable for input/output
and the second half 8 points is unacceptable area for
this module.
16 points
input/output
16 Acceptable for 16 points as I/O module.
32 points
input/output, I/O
32
Acceptable for 32 points as input, output, and
I/O module.
Special I/O
(64 points
input/output)
16
Although 16 points are assigned, this is a dummy area
not used in this module.
-Inthe 64 points I/O module, the relay area for
special I/O module can be used as I/O module.
Special I/O
(except for 64
points)
16
Although 16 points are assigned, this is a dummy area
not used in this module.
Option
I/O link
DeviceNet
Vacant slot 16 Allocation for 16 points.
[3] Maximum number of input/output points and allocation of input/output relays
Each control module has own maximum number of control input/output points. However, number of relay
points that affect maximum number of control input/output points varies with each model. Be careful that
these are different from number of relay allocation points.
Maximum number of JW-32CUM1 control input/output points
Number of relay points and number of installable modules on each module
epyteludoM
yalerforebmuN
tceffatahtstniop
rebmunmumixam
stniopO/Ilortnocfo
forebmuN
noitacolla
O/Ifostniop
syaler
mumixaM
forebmun
dellatsni
seludom
tahtskcaR
llatsninac
seludomtuptuo/tupnitniop8stniop61stniop61seludom067ot0kcaR
seludomtuptuo/tupnitniop61stniop61stniop61seludom067ot0kcaR
seludomO/I/tuptuo/tupnitniop23stniop23stniop23seludom067ot0kcaR
laicepS
O/I
eludom
tutuo/tupnitniop46*stniop46stniop61
seludom233ot0kcaR
tniop46nahtrehtO
tuptuo/tupni
0stniop61
eludomnoitpO0stniop61seludom40kcaR
eludomretsamknilO/I0stniop612*0kcaR
eludomretsamteNeciveD0stniop613*0kcaR
tolstnacaV0stniop61---7ot0kcaR
rebmunmumixaM
O/Ilortnocfo
stniop
rebmunmumixaM
yalerO/Ifo
stniopnoitacolla
aerayalerO/I
citamotuA
noitartsiger
elbatetaerC
stniop4201stniop4051
コ0004 to コ0277 コ0004 to コ1577
*1: The 64-point input/output module uses special I/O relay area (コ3000 to コ3777) for its control
relay.
*2: Maximum of one JW-23LMH module (operation modes 7 or 8 only).
*3: Maximum of three JW-20DN modules.