Items Specifications
Installed position Slot for the power supply module of basic/expansion rack panel
Input voltage 85 to 264 VAC (47 to 63 Hz)
Power consumption 70 VA or less
Surge current 40 A or less (200 VAC)
Leakage current 1mA or less (at 100 VAC), 3.5mA or less (at 200 VAC)
Output voltage 5 VDC
Output current 4.5 A
Rated output current 0 to 4.5A
Output hold time 10 ms or more
Protection
circuit
Overcurrent Dropping automatic reset system
Overvoltage Shut-OFF type manual reset system
Halt output
Function Relay output becoming OFF when the control module stops.
Load voltage 100/200 VAC (50/60 Hz),30 VDC
Load current 1A max.
Leakage current 1 mA (200 VAC)
Insulation resistance 500 VDC, 10M ohms or more
Dielectical strength 1500 VAC for 1 minute
Display POWER LED (green), RUN LED (green)
External wire connection 6P terminal block
Operation temperature 0 to 55 degrees
Storage temperature -20 to 70 degrees
Operation ambient humidity 35 to 90%RH (without condensation)
Operation atmosphere Free from corrosive gas
Vibration resistance
JIS C 0911 or equivalent
-Multiple vibration width: 0.15 mm (10 to 57 Hz), 9.8 m/s
2
(57 to
150 Hz), Number of sweeps: 10 (1 octave/minute), three
directions (X, Y, and Z)
Shock resistance
JIS C 0912 or equivalent, 147m/s
2
(3 times in each X, Y and Z
directions)
Noise immunity
1000 Vp-p 1µs (by noise simulator between the power line and
rack panel)
Weight Approx. 410g