Required changes to wall cabinets
and exhaust fans above the built-in
combined product as well as minimum
heights from the oven board are shown
in Figure 1. The exhaust fan should be
at a minimum height of 65 cm from the
cooktop. If there is no exhaust fan, the
height must be at least 70 cm.
HOB
Minimum
42 cm
Minimum
42 cm
Minimum 65cm
(with hood)
Minimum 70cm
(without hood)
INSTALLATION OF BUILT-IN
OVEN
550 mm
595 mm
576 mm
min. 590mm
min. 600mm
595 mm
575 mm
min. 555mm
max. 560mm
max. 580mm
550 mm
557 mm
595 mm
575 mm
min.590mm
min.
5mm
min. 600mm
595 mm
576 mm
min. 555mm
min. 560mm
max. 580mm
2 x
Insert the oven into the cabinet by push-
ing it forward. Open the oven door and
insert 2 screws in the holes located
on the oven frame. When the product
frame touches the wooden surface of
cabinet, tighten the screws.
Worktop
min.
25 mm
min.
50 mm
Built-in hob
Built-in oven
If the oven is installed under a hob, the
distance between the worktop and the
top panel of the oven must be minimum
50 mm and the distance between the
worktop and the top of control panel
must be minimum 25 mm.
WIRING AND SAFETY OF BUILT-
IN OVEN
The instructions given below must be
followed without fail during wiring:
Screw the earthing cable at the earth-
ing mark. Supply cable connection
must be as shown in Figure 6. If there
is no earthed outlet conforming to
regulations in the installation envi-
ronment, call your authorized service
supplier immediately.
The earthed outlet must be close to
the appliance. Never use an exten-
sion cord.
The supply cable should not contact
the product’s hot surface.