Installation guide

iNSTALLATION MANUAL
frame where the ground screw was originally installed. See
Figure 8.
Make sure all screws are tightened securely and replace the
rear access cover and secure with screw. See Figure 6.
3-WIRE CONNECTION INSTRUCTIONS
For existing installations ONLY, refer to Figure 9.
t Follow the power supply cord kit manufacturer's Installation
Instructions and install the strain relief clamp. See Figure 7.
2 Connect the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 9.
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
3 A ground strap is installed on this range which connects the
center terminal of the neutral terminal block to the range
chassis. The ground strap is connected to the range by the
center, lowest screw. See Figure 9. The ground strap must not
be removed unless National, State or Local Codes do not permit
use of a ground strap.
If the ground strap is removed for any reason, a
separate ground wire must be connected to the separate ground
screw attached to the range chassis and to an adequate ground
SOl.lrce.
4 Make sure all connections are tightened securely and replace
the rear access cover and secure with screw. See Figure 6.
Connect
icn_ lgrho_rnd_
strap. Discard
ground strap
and ground
plate. --
Connect green
insulated copper
ground wire with
gl
here.
Figure 8
Note: Install strain
clamp. Center or
white wire must always
be attached to the
center terminal on
)lock.
block
Connect line 2 here.
Connect neutral (white
-or center) here.
A user supplied strain
relief clamp must be
installed at this
location. It requires 1
3/8" (3.5 cm) diameter
cord kit hole.
O
_. Terminal block
Connect line _ _1
1here. _ _4_(L_ _ /Connect line 2 here.
Ground strap_ _ =_ _ Connect neutral
\ /here.
Note: Install strain X_. L_) )
_-_-4 A user supplied
relief clamp. Center _J _/ "_ _ Lstrain relief clamp
must always be _'-'_-_'_ I l
attached to the _ / / } _] must be installed
center terminal on _ _ J at this location. It
block. ._ _requires 1 3/8"
(3.5 cm) diameter
F_&ll_e _ _ i _ II cord kit hole.
3 & 4.WIRE P_RiglANENT W|RE CONNECTIONS
3-wire permanent connection - %llow steps 1, 2 and 5 below.
4-wire permanent connection - follow all steps below.
Before wiring the range, review the suggested power source location
drawings in Figure 2. If connecting to a 4-wire electrical system:
t Follow the manufactm'er's Installation Instructions for installing
the strain relief clamp.
2 Strip insulation away from the ends of the permanent wiring
for line 1, line 2 and neutral; also strip ground wire on 4-wire
connections. Tighten all 3 or 4-wire leads to the terminal block.
Follow wire locations shown in Figure 10.
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
_[_ For 3-wire permanent connection skip steps 3 and 4
and continue with step 5.
3 Disconnect the ground strap. Remove the factory installed
ground screw and plate to release the factory installed copper
ground strap from frame of the range. Cut and discard the
copper strap from the terminal block. KEEP the ground screw,
ground plate and go to step 4.
4 Connect the green ground wire lead to the frame of the range
using the ground screw and plate as shown in Figure 11.Be sure
to install using the same hole in the frame where the ground
screw was originally installed.
5 Make sure all connections are tightened securely and replace
the rear access cover and secure with screw. See Figure 6.
Non-terminated field wire compression connections
must be set at approximately 90 in./lb.
terminal
block _ _
line 1_ line 2
// neutral rJ_ground_rap
_j_// _ground plate
Figure t O screw
/