3
Make sure all connections are tightened securely and replace
the rear access cover. Se e Figure 7.
GROUNDING INSTRUCTIONS- ONLY 3-WIRE CONNECTIONS:
A ground strap is i nstalled on this range which connects the center
terminal of the neutral terminal block t o the range chassis. The
ground strap is connected to the range by the center, lowest screw
SeeFigure9. ThegroundstrapmustnotberemovedunlessNational
State or Local Co des do not permit us e of a ground strap.
Note: If the ground strap is removed for any reason, a separate
ground wire must be connected to the separat e ground screw
attached to the range chassis and to an adequate ground source
3 & 4-WIRE PERMANENT WIRE C ONNECTIONS
3–wir e permanent connection follow steps 1, 2 and 5 below.
4–wire permanent connection follow all steps below.
Beforewiringther ange,reviewthesuggestedpowersourcelocation
drawings in Figure 2. I f c onnecting to a 4 -wire electrical system:
1
Follow the manufact urer s Installation Instructions supplied
with the stra in relief clamp and install.
2
Strip insulation away from the ends of the permanent wiring
for line 1, line 2 and neutral; also strip ground wire on 4-wire
G
r
o
u
n
d
s
t
r
a
p
t
e
r
m
i
n
a
l
b
l
o
c
k
Note: Install strain-relief
clamp. Center or white
wire must always be
attached to the center
terminal on block.
Connect neutral (white
or center) here.
Connect line
1 here.
Connect
line 2
here.
A user supplied strain-relief
clamp must be installed at
this location. It requires
1
3
/
8
-inches (3.5 cm)
diameter cord kit hole.
Figure 9
t
e
rm
i
n
a
l
b
l
o
c
k
w
h
i
t
e
r
e
d
g
r
e
e
n
A user supplied strain-
relief clamp must be
installed at this location.
It requires 1
3
/
8
-inches
(3.5 cm) diameter cord
kit hole.
Connect green insulated
copper ground wire with
ground screw here.
Cut ground strap.
Discard ground strap &
ground plate.
Connect neutral (white
or center) here.
Connect line
1 here.
Connect
line 2
here.
b
l
a
c
k
Note: Install strain-relief
clamp. Center or white
wire must always be
attached to the center
terminal on block.
Figure 8
4-WIRE CONNECTION
3-WIRE CONNECTION
Figure 10
ground
screw
ground
wire lead
ground
plate
proper ground for
4-wire permanent
connection
Figure 11
4-WIRE PERMANENT CONNECTION ONLY
FOR 3 & 4-WIRE PERMANEN T CONNECTIONS
connections.Tightenall3or4-wireleadstotheterminalblock.
Follow wire locations shown in Figure 10.
IMPORTANT
DO NOT LOOSEN the factory installed nut
connections which secure the ra nge wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
Note: For3-wir e permanentconnection skipsteps3 and 4and
continue with step 5.
3
Disconnect the ground strap. Remove the factory installed
ground screw and plate to release the factory installed copper
ground strap from frame of the range. Cut and discard the
copperstrapfromtheterminalblock.KEEPthegroundscrew,
ground plate and go to step 4.
4
Connect the green ground wire lead to the frame of the range
usingthegroundscrewandplateasshowninFigure11.Besure
to in stall using t he same hole in the fra me where the ground
screw was originally installed.
5
Make sure all connections are tightened securely and replace
the rear access cover. Se e Figure 7.
Note:Non-terminatedfieldwirecompressionconnectionsmust
be set at app roximately 90 in./lbs.
terminal
block
ground
screw
ground plate
ground strap
line 2
neutral
line 1