R KC-F30J AIR PURIFIER with Humidifying Function OPERATION MANUAL “Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation. CLEAN ION SHOWER Free standing type KC-F30J_EN.indd 1 *The number in this technology mark indicates the approximate number of ions supplied into 1 cm3 of air, which is measured around the center of a room (with the “High-Density Plasmacluster 7000” applicable floor area), at a height of 1.
Before operating your new air purifier, please read the following The air purifier draws in room air through the air intake, circulates it through a Pre-Filter, a Deodorizing Filter and a HEPA Filter inside the unit, and then discharges it through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the filter and also helps absorb odors. The Deodorizing Filter gradually absorbs odors as they pass through the filter.
ENGLISH FEATURES A Unique Combination of Air Treatment Technologies Triple Filtration System + Plasmacluster + Humidification TRAPS DUST* Pre-Filter traps dust and other large airborne particles. DECREASES ODORS CONTENTS IMPORTANT SAFETY INSTRUCTIONS...... E-2 PART NAMES................................................ E-4 PREPARATION............................................. E-6 OPERATION.................................................. E-8 Deodorizing filter absorbs many common household odors.
IMPORTANT SAFETY INSTRUCTIONS Always follow basic safety precautions when using electrical appliances, including the following: WARNING - Always observe the following to reduce the risk of electrical shock, fire, or injury: • Read all instructions before using the unit. • Use only a 220-240 volt outlet. • Do not use the unit if the power cord or plug is damaged or if the connection to the wall outlet is loosened. • Periodically remove dust from the power plug.
CAUTIONS CONCERNING OPERATION • Do not operate the unit without the filters and the Humidifying Tray properly installed. • Keep the unit away from water. • Do not wash and reuse the HEPA filter and Deodorizing filter. Doing so will not improve filter performance and can also cause electric shock or operating malfunctions. • Clean the exterior with a soft cloth only. Do not use volatile liquids or detergents. Doing so can damage or crack the exterior of the unit.
PART NAMES FRONT / BACK FRONT 1 CLEAN ION SHOWER 2 3 BACK BACK 4 13 5 6 14 7 8 9 15 10 16 11 12 1 2 3 4 5 6 7 8 (Plug shape varies by country.) 9 10 11 12 13 14 15 16 Operation Panel / Display (Ref.E-5) Handle (2 Locations) Main Unit Air Outlet Filter Frame Humidifying Filter Float (in Filter Frame) Tray Handle Humidifying Tray Float HEPA Filter Deodorizing Fiter Sensor (internal) Back Panel (Pre-Filter) Air lnlet Power Cord / Plug E-4 KC-F30J_EN.
OPERATION PANEL / DISPLAY 6 7 5 4 3 2 1 Display Dust Sign Indicates the air purify level 3 colors. Green Clean Orange Red Impure 8 9 Humidify Light Humidity / Temperature monitor Green................. Humidify ON Indicates the approximate humidity / temperature level in the room. Green................. Unit needs water (Flashing) temperature 0 to 50ºC is displayed at 1ºC-intervals Off ......................
PREPARATION PREPARATION Alwaysbe besure sure remove Always to to remove the the power plug plugfrom fromthe thewall walloutlet. outlet. power FILTERINSTALLATION INSTALLATION FILTER RE 1 Remove the Back Panel. Back Panel 2 HEPA filter Deodorizing filter Remove the Filters from the plastic bag. Humid The u 1 2 Place the surface with tag. 3 Install the Filters in the correct order as shown. Tag 3 Deodorizing filter (The same on both sides.) HEPA filter 4 Click Install the Back Panel.
REFILLING THE HUMIDIFYING TRAY Humidify air passed through by vaporizing water pumped up from Humidifying Tray. The unit can be used even without water in the Humidifying Tray. 1 Pull out the Humidifying Tray. CLEAN ION SHOWER CLEAN ION SHOWER CAUTION 2 Fill the Humidifying Tray with tap water by method A or B . A FULL CAUTION ・The Filter Frame is floated up when water is filled. • When carrying the Humidifying Tray, hold it with both hands or grip the Tray Handle.
OPERATION Power ON / OFF START STOP • Select the desired fan speed by . • Unless the power cord has been unplugged, the operation starts in the previous mode it was operated in. CLEAN ION SHOWER Releases high-density Plasmacluster ions and discharges strong air flow for 60 minutes. START NOTE • When the operation finishes, the unit will return to the prior operation mode. It is able to change the other mode during this mode. FAN SPEED Select the desired fan speed.
USEFUL FUNCTION LIGHT CONTROL You can set the front surface Indicators to OFF when the Indicator is too bright. ON OFF Press more than 3 seconds. Press more than 3 seconds. Plasmacluster Ion ON/OFF When Plasmacluster Ion is ON, the Plasmacluster Ion Indicator Light is on. (blue) OFF ON Press more than 3 seconds. NOTE Press more than 3 seconds. ON OFF Changing display (humidity / temperature) You can select either humidity or temperature at the time to be displayed.
USEFUL FUNCTION C Off TIMER Select the length of time you want. The unit automatically stops once the selected time is reached. 1 hour 2 hours 4 hours 8 hours CANCELLATION CA NOTE Sen • Pressing displays the remaining time. • To reset the operating time, press while the remaining time is being displayed. Unit (Ref Auto RESTART If the unit is unplugged or if there is a power failure, the unit will resume operation with the previous settings after power is restored. The default setting is ON.
CAREAND ANDMAINTENANCE MAINTENANCE CARE FILTER INDICATOR After performing maintenance, reset the Filter Indicator. The filter Indicator Light will turn on after approximately 720 hours. (30 days × 24 hours =720 hours) This is a reminder to perform the maintenance described below. (Ref.E-11,E-12,E-13,E-14) In case of using at the location where air pollution and odor are significant, maintain frequently even if Filter Indicator Light is not ON. HEPA Filter (Ref.E-14) Deodorizing Filter (Ref.
CARE AND MAINTENANCE Alw from HUMIDIFYING FILTER / TRAY Odor occurrence may be suppressed when washing Humidifying Filter and Humidifying Tray with water carefully even if the Filter Indicator Light is not ON. Remove the Humidifying Filter from the Tray. Turn down Remove Pull up 1 2 Open Turn the handle down on the reverse side. CAUTION Remove the Filter Frame. Remove the Humidifying Filter. • Drops of water may drip from the Humidifying Filter and the Filter Frame.
Always be sure to remove the power plug Always be sure to remove the power plug from the the wall wall outlet. outlet. from ater Recommended descaling solutions • Citric acid (available at some drugstores) • 100% bottled lemon juice with no pulp. stir well! 2 ¹⁄ ² cups of water 2 stir well! 3 cups of water NOTE ¹⁄ ⁴ 1. Soak in water with a descaling solution for about 30 minutes. CAUTION • When using lemon juice as your descaling solution, allow to soak for longer. 2.
CARE AND MAINTENANCE UNIT Alw from Wipe with a dry, soft cloth. CLEAN ION SHOWER FI LIF CAUTION • Do not use volatile fluids. Benzene paint thinner or polishing powder can damage the surface. • Do not use detergents. Detergent ingredients can damage the unit. We re sever •HE •Deo •Hum CLEANING FILTERS Gently remove dust with an appropriate cleaning tool, such as a vacuum cleaner with the proper attachment.
Always be sure sure to toremove removethe thepower powerplug plug Always be from from the the wall wall outlet. outlet. FILTER REPLACEMENT LIFE OF FILTERS Filter life varies depending on the room environment, usage conditions, and location of the unit. Lifespan of HEPA filter and Deodorizing filter and replacement suggestions are based on purifying a room in which 5 cigarettes are smoked per day and the unit's dust collection and deodorizing performance has declined to half the level of a new filter.
TROUBLESHOOTING Before calling for service, review the troubleshooting chart below to make sure that the problem is not a unit malfunction. SYMPTOM Pow Fan REMEDY (the following are not due to a malfunction) CLE Odor and smoke persists. • Check the filters. If they appear to be extremely dirty, clean or replace them. (Ref. E-11,E-12,E-13,E-14,E-15) The Dust Sign light is green even when the air is not clean. • The air may have been dirty when the unit was plugged in.
SPECIFICATIONS 220-240V 50-60Hz Power supply Fan Speed Adjustment 3 CLEAN AIR CLEAN AIR &HUMIDIFY MED SLEEP Fan Speed (m /hour) 180 125 52 Rated Power (W) 27 12 4.1 Noise Level (dBA) 48 38 21 Fan Speed (m /hour) 180 125 52 Rated Power (W) 27 12 4.1 3 ain. MAX Noise Level (dBA) 48 38 21 Humidification (mL/hour)*1 350 280 140 Recommended Room Size (m2)*2 ~21 2 ~17 High density Plasmacluster ion recommended room size (m )*3 Humidifying Tray Capacity (L) 1.
FOR CUSTOMER ASSISTANCE WARRANTY Consumer Electronic Products Congratulations on Your Purchase! This Sharp product is warranted against faults in material and manufacture for the period as stated in the table below. If service is required during the warranty period, please contact your nearest Sharp Approved Service Centre. These repairs would be carried out at no charge to the owner, subject to the conditions specified herein.
FOR LOCATION ENQUIRIES WITHIN AUSTRALIA REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.au OR CALL SHARP LOCAL CALL 1 300 135 022 SHARP CORPORATION OF AUSTRALIA PTY LTD FOR PRODUCTS PURCHASED NEW ZEALAND CONTACT YOUR SELLING DEALER/RETAILER OR CALL SHARP CUSTOMER SERVICES TELEPHONE: 09 573 0111 FACSIMILE: 09 573 0113 WEB: www.sharpnz.co.nz SHARP CORPORATION OF NEW ZEALAND LIMITED SPform019(NOV 2016) E-19 KC-F30J_EN.
SHARP CORPORATION OF AUSTRALIA PTY.LTD. A. B. N. 40 003 039 405 2 JULIUS AVENUE, NORTH RYDE, N.S.W. 2113 P.O.BOX 84, MACQUARIE PARK. N.S.W 2113 SHARP CORPORATION OF NEW ZEALAND LIMITED 59 HUGO JOHNSTON DRIVE PENROSE, AUCKLAND FACTORY USE ONLY Printed in China TINS-A000KKRZ 18J - 1 KC-F30J_EN.