Operating Manual

4.6
Preparing the electrical connections for the parallel mode .............................. 46
4.7
Connection concept of multiple BMZ ESS 7.0 batteries with one or more battery
inverters .................................................................................................................. 47
4.7.1
Communication ................................................................................................................... 47
4.7.2
Output contact .................................................................................................................... 49
4.7.3
Laying the power cable ........................................................................................................ 53
4.8
Configuration of the ESS parallel mode .............................................................. 54
4.8.1
1-phase operation of a SMA Sunny Island inverter on 1 ESS battery .................................. 54
4.8.2
1-phase operation of a SMA Sunny Island inverter on 2 ESS batteries ............................... 54
4.8.3
1-phase operation of a SMA Sunny Island inverter on 3 ESS batteries ............................... 55
4.8.4
3-phase operation of a SMA Sunny Island inverter on 3 ESS batteries ............................... 56
4.8.5
3-phase operation of a SMA Sunny Island inverter on 4 ESS batteries ............................... 57
4.8.6
3-phase operation of a SMA Sunny Island inverter on 5 ESS batteries ............................... 58
4.8.7
3-phase operation of a SMA Sunny Island inverter on 6 ESS batteries ............................... 59
4.9
Configuration of the ESS battery ......................................................................... 60
4.9.1
System structure .................................................................................................................. 60
4.9.2
Addressing the batteries ...................................................................................................... 60
4.10
Definition of the battery mode during commissioning and parameter
configuration .......................................................................................................... 60
4.10.1
Single: .................................................................................................................................. 60
4.10.2
Master: ................................................................................................................................ 60
4.10.3
Slave:.................................................................................................................................... 60
4.11
Work step sequence to configure the parameters of batteries ........................ 61
4.12
Work step sequence to commission the batteries ............................................ 62
4.13
Configuration of firmware for parallel mode ..................................................... 63
4.13.1
Setting the master battery mode ....................................................................................... 63
4.13.2
Setting the master battery address ..................................................................................... 64
4.13.3
Setting the slave battery mode ........................................................................................... 65
4.13.4
Setting the slave battery address ........................................................................................ 65
4.14
Commissioning the parallel connection of multiple batteries .......................... 66
4.14.1
Switch-on sequence ............................................................................................................. 66
4.14.2
Stand-by mode of a slave battery: ....................................................................................... 66
4.14.3
Switch-on criterion of the slave battery: ............................................................................. 66
4.14.4
Example 1: ........................................................................................................................... 67
4.14.5
Example 2: ........................................................................................................................... 67
4.14.6
Example 3: ........................................................................................................................... 68
4.15
Checking the parallel connection of multiple batteries .................................... 69
4.15.1
Check the number of connected (detected) batteries ........................................................ 69
4.15.2
Check the number of batteries for which the main relay is closed ..................................... 70
4.16
Adding new batteries ............................................................................................ 70
4.17
Checking the connections of parallel battery systems ..................................... 71
4.17.1
Switching the battery storage system on and off ................................................................ 71
4.17.1
Configuring the parameters of the inverter ........................................................................ 73