Specifications

DISASSEMBLY INSTRUCTIONS
B1-1
1. REMOVAL OF MECHANICAL PARTS
AND P.C. BOARDS
1-1: BACK CABINET (Refer to Fig. 1-1)
1.
2.
Remove the 19 screws 1.
Remove the Back Cabinet in the direction of arrow.
Fig. 1-1
Back Cabinet
1-3: PCB ASS'Y (Refer to Fig. 1-3)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Disconnect the following connectors:
(CP506, CP507, CP508, CP510, CP511, CP512).
Remove the 9 screws 1.
Remove the Holder AC-Inlet and Power PCB in the
direction of arrow (A).
Disconnect the following connectors:
(CP802, CP803, CP2200, CP3201, CP3602, CP7203).
Remove the 10 screws 2.
Remove the Shield Scaler and Scaler PCB in the
direction of arrow (B).
Disconnect the following connectors:
(CP301, CP303, CP2403, CP2404, CP4202).
Remove the 6 screws 3.
Remove the DigitalPCB and AV PCB in the direction of
arrow (C).
Remove the 2 screws 4.
Remove the Remocon PCB in the direction of arrow (D).
Remove the 8 screws 5.
Remove the Plate Button, Operation PCB and Operation
2 PCB in the direction of arrow (E).
Fig. 1-3
1-2:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Remove the 4 screws 1.
Remove the Stand Ass'y in the direction of arrow (A).
Remove the 4 screws 2.
Remove the 6 screws 3.
Remove the Angle Back 1/2 in the direction of arrow (B).
Remove the 4 screws 4.
Remove the Plate Jack 2 in the direction of arrow (C).
Remove the 11 screws 5.
Remove the Plate Jack 1 and Shield Jack in the direction
of arrow (D).
Fig. 1-2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
3
3
3
3
3
3
4
5
4
5
5
Stand Ass'y
Angle Back 2
Angle Back 1
Plate Jack 2
Plate Jack 1
Shield Jack
(A)
(B)
(C)
(D)
STAND ASS'Y/ANGLE BACK 1/2/PLATE JACK 1/2
(Refer to Fig. 1-2)
1
1
1
1
1
1
1
1
1
Holder AC-Inlet
Power PCB
(A)
2
2
2
2
2
2
2
2
2
2
Shield Scaler
Scaler PCB
3
3
3
3
3
3
Digital PCB
AV PCB
(B)
(C)
4
4
Remocon PCB
(D)
5
5
5
5
5
(E)
Operation PCB
Plate Button
1
5
5
5
5
Operation 2 PCB