Service manual
12
LC-20VM2
LC-121M2E
LC-150M2E
Adjusting range
Page Item Minimum Maximum Initial Remarks
8 N358 R-Y PHASE 0 3 2
N358 B-Y PHASE 0 3 1
N443 R-Y PHASE 0 3 2
N443 B-Y PHASE 0 3 1
PAL-M R-Y PHASE 0 3 2
PAL-M B-Y PHASE 0 3 1
PAL R-Y PHASE 0 3 2
PAL B-Y PHASE 0 3 1
SECAM R-Y PHASE 0 3 2
SECAM B-Y PHASE 0 3 1
COLOR 0 127 60
SCONT 0 31 18
9 SPEED 9600 600/1200/2400/4800/9600/19.2k
PARITY NONE NONE/EVEN/ODD
TIME OUT 0 FF 0 Hexadecimal indication
10 GAMMA TEST OFF ON/OFF
AV V0 0 255 240
AV V0 BIAS 0 255 127
AV V16 0 255 185
AV V16 BIAS 0 255 127
AV V32 0 255 123
AV V32 BIAS 0 255 118
AV V48 0 255 75
AV V48 BIAS 0 255 127
AV V63 0 255 40
AV V63 BIAS 0 255 127
11 GAMMA TEST OFF ON/OFF
RGB V0 0 255 240
RGB V0 BIAS 0 255 127
RGB V16 0 255 185
RGB V16 BIAS 0 255 127
RGB V32 0 255 123
RGB V32 BIAS 0 255 118
RGB V48 0 255 75
RGB V48 BIAS 0 255 127
RGB V63 0 255 40
RGB V63 BIAS 0 255 127
6-5. Adjustment process mode special key operation
With the “AUTO PRESET” key on the remote control Forward movement of the page
With the “MANUAL MEMORY” key on the remote control Moves to the first line of the current page
With the “MENU” key on the remote control or the main unit Forward movement of the selection item
With the “PICTURE SELECTION” key on the remote control Backward movement of the selection item