Service manual

13
LC-20VM2
LC-121M2E
LC-150M2E
6-6. Service Adjusting
6-6-1. Main chassis adjustment
Adjustment Adjusting conditions Adjusting method
1 +B Adjustment 1. Connect the DC voltmeter to 1. Adjust the DC/DC 5V line output
(+B ADJ Item) TP1101 voltage so as to get 5.0±0.05V.
(DAC 16ch )
2 Setting
(MODEL) MODEL V2U
(SYSTEM) SYSTEM AUTO
(COPY GUARD) COPY GUARD ON
(MASK) MASK OFF
3 Counter-bias adjustment 1. Set the AV1 mode to set signal 1. Adjust COM so as to minimize the
(COM Item) noninput state. waveform peak-peak.
2. Fit the specified adjusting instrument (DAC2 2ch)
to the screen center.
3. Observe the adjusting instrument
output on the oscilloscope.
4 NTSC / PALM OSC 1. Input the NTSC monoscope 1. Adjust OSC so as to get the normal
adjustment pattern to AV1. screen.
(NTSC/PALM OSC Item)
6-6-2. N358 signal adjustment
Adjustment Adjustment conditions Adjustment method
1 Brightness adjustment 1. Input the NTSC standard color bar 1. Adjust N358 BRIGHTNESS, and
(N358 BRIGHTNESS Item) to AV1. adjust the black level of G output so
2. Connect the oscilloscope to TP821 as to get DC 0.35±0.05V.
(IC316, pin7, G output).
2 R CUTOFF adjustment 1. Input the NTSC standard color bar 1. Adjust R CUTOFF so as to equalize
(R CUTOFF Item) to AV1. the black levels of green and red.
2. Connect CH1 of the oscilloscope to
TP821 (IC316, pin7, G output).
3. Connect CH2 of the oscilloscope to
TP819 (IC315, pin1, R output).