Service manual

19
LC-20VM2
LC-121M2E
LC-150M2E
Adjustment Adjusting conditions Adjusting method
4 RGB Contrast adjustment 1. Input the test pattern to RGB. 1. Adjust RGB CONTRAST so as to
(RGB CONTRAST Item) 2. Connect the oscilloscope to TP821 get 2.5±0.1Vp-p between the 100%
(IC316, pin7, G output). white and GND.
5 RGB R DRIVE adjustment 1. Input the test pattern to RGB. 1. Adjust so as to get 100% white level
(RGB R DRIVE Item) 2. Connect CH1 of the oscilloscope to identical with that of green.
TP821 (IC316, pin7, G output).
3. Connect CH2 of the oscilloscope to
TP819 (IC315, pin1, R output).
6 RGB B DRIVE adjustment 1. Input the test pattern to RGB. 1. Adjust so as to get 100% white level
(RGB B DRIVE Item) 2. Connect CH1 of the oscilloscope to identical with that of green.
TP821 (IC316, pin7, G output).
3. Connect CH2 of the oscilloscope to
TP820 (IC316, pin1, B output).
6-6-9. Finished adjustment
(1)N358 finished adjustment
Adjustment Adjusting conditions Adjusting method
1 Confrontation bias 1. A confrontation adjustment pattern is 1. It is adjusted so that the flicker of the
adjustment displayed. image plane may stop in the
(The 12th-page COM Item) confrontation adjustment pattern.
2 Black level adjustment 1. A JA-5CH signal is displayed. 1. It confirms that the third gradation is
(The 12th-page N358 a cut-off point from the left of the
BRIGHTNESS Item) gradation pattern.
3 White balance adjustment 1. A JA-6CH signal is displayed. 1. White balance in comparison with the
(The 12, 13th-page Typ monitor.
N358 R CUTOFF
N358 B CUTOFF
N358 R DRIVE
N358 B DRIVE Item)