NUJC360B MEA Countries

NU-JC360B
Maximum power P

360 W
Open-circuit voltage V

40.26 V
Short-circuit current I

 A
Voltage at point of maximum power V

 V
Current at point of maximum power I

10.60 A
Module efficiency
 %
STC = Standard Test Conditions: irradiance 1,000 W/m², AM 1.5, cell temperature 25 °C.
Rated electrical characteristics are within ±10 % of the indicated values of I
sc
, V
oc
and 0 to +5 % of P
max
(power measurement tolerance ± 3 %).
Reduction of efficiency from an irradiance change of 1,000 W/m² to 200 W/m² (T
module
= 25 °C) is less than 3 %.
NU-JC360B
Maximum power P

 W
Open-circuit voltage V

38.04 V
Short-circuit current I

 A
Voltage at point of maximum power V

30.57 V
Current at point of maximum power I

8.81 A
NMOT = Nominal Module Operating Temperature: 45 °C, irradiance 800 W/m², air temperature of 20 °C, wind speed of 1 m/s.
Electrical data (NMOT)
Electrical data (STC)
Cells 
Front glass Anti-reflective high transmissive low iron tempered glass, 3.2 mm
Frame Anodized aluminium alloy, black
Backsheet Black
Cable 4.0 mm², length 1,250 mm
Connection box IP68 rating, 3 bypass diodes
Connector MC4 (Multi Contact, Stäubli), IP68
Modules per pallet 31 pcs
Pallet size
(L × W × H)
1.80 m x 1.13 m x 1.24 m
Pallet weight Approx. 685 kg
Packaging data General data
Length 1,765 mm
Width 1,048 mm
Depth 35 mm
Weight 21.0 kg
P

-0.347 %/°C
V

-0.263 %/°C
I

0.057 %/°C
Mechanical data
Temperature coefficient
Dimensions (mm)
Maximum system voltage 1,000 V DC
Over-current protection 20 A
Temperature range -40 to 85 °C
Max. mechanical load
(snow/wind)
2,400 Pa
Tested snow load
(IEC61215 test pass*)
5,400 Pa
Limit values
Note: Technical data is subject to change without prior notice. Before using SHARP products, please request the latest data sheets from SHARP. SHARP accepts no responsibility for damage to devices which have been equipped with SHARP products on the basis of unverified
information. The specifications may deviate slightly and are not guaranteed. Installation and operating instructions are to be found in the corresponding handbooks, or can be downloaded from www.sharp.eu. This module should not be directly connected to a load.
SHARP Electronics GmbH
Energy Solutions
Nagelsweg 33 – 35
20097 Hamburg, Germany
T: +49 40 2376 2436
E: SolarInfo.Europe@sharp.eu
NUJC3B10EN2012
Sharp.co.uk/energysolutions | @SHARPSolarEMEA
*Please refer to SHARP’s installation manual for details.
Grounding hole
Mounting hole