NUJD440 EU Countries

NU-JD440
Maximum power P

440 W
Open-circuit voltage V

49.77 V
Short-circuit current I

11.49 A
Voltage at point of maximum power V

41.20 V
Current at point of maximum power I

10.68 A
Module efficiency
19.9 
STC = Standard Test Conditions: irradiance 1,000 W/m², AM 1.5, cell temperature 25 °C.

sc
, V
oc

max

Reduction of efficiency from an irradiance change of 1,000 W/m² to 200 W/m² (T
module

NU-JD440
Maximum power P

329.14 W
Open-circuit voltage V

46.07 V
Short-circuit current I

9.21 A
Voltage at point of maximum power V

36.98 V
Current at point of maximum power I

8.90 A
NMOT = Nominal Module Operating Temperature: 45 °C, irradiance 800 W/m², air temperature of 20 °C, wind speed of 1 m/s.
Electrical data (NMOT)
Electrical data (STC)
Cells Half-cut cell mono, 166 mm x 83 mm, 9BB, 2 strings of 72 cells in series
Front glass Anti-reflective high transmissive low iron tempered glass, 3.2 mm
Frame Anodized aluminium alloy, silver
Backsheet White
Cable 4.0 mm², length 1,670 mm [or on request (+) 365 mm, (-) 50 mm]
Connection box IP68 rating, 3 bypass diodes
Connector C1, IP68
Modules per pallet 27 pcs
Pallet size
(L × W × H)
2,16 m x 1,13 m x 1,24 m
Pallet weight Approx. 736 kg
Packaging data General data
Length 2,108 mm
Width 1,048 mm
Depth 40 mm
Weight 25.5 kg
P


V


I


Mechanical data
Temperature coefficient
Dimensions (mm)
Maximum system voltage 1,500 V DC
Over-current protection 20 A
Temperature range -40 to 85 °C
Max. mechanical load
(snow/wind)
2,400 Pa
Tested snow load
(IEC61215 test pass*)
5,400 Pa
Limit values
Note: Technical data is subject to change without prior notice. Before using SHARP products, please request the latest data sheets from SHARP. SHARP accepts no responsibility for damage to devices which have been equipped with SHARP products on the basis of unverified
information. The specifications may deviate slightly and are not guaranteed. Installation and operating instructions are to be found in the corresponding handbooks, or can be downloaded from www.sharp.eu. This module should not be directly connected to a load.
SHARP Electronics GmbH
Energy Solutions
Nagelsweg 33 – 35
20097 Hamburg, Germany
T: +49 40 2376 2436
E: SolarInfo.Europe@sharp.eu
NUJD44EN2012
Sharp.co.uk/energysolutions | @SHARPSolarEMEA
*Please refer to SHARP’s installation manual for details.
Grounding hole
Mounting hole
Mounting hole