Operation Manual

31
E
Controlling the Monitor with a PC (RS-232C)
You can control this monitor from a PC via RS-232C (COM
port) on the PC.
PC connection
Connect with RS-232 straight cable between the PC’s COM
port (RS-232C connector) and the RS-232C input terminal on
the monitor.
RS-232 straight cable
(commercially available)
To COM port
PC
RS-232C
input terminal
Communication conditions
Set the RS-232C communication settings on the PC to match
the monitor’s communication settings as follows:
Baud rate 9600bps
Stop bit
1 bit
Data length 8 bits Flow control None
Parity bit None
Communication procedure
n
Command format
When a command is sent from the PC to the monitor, the
monitor operates according to the received command and
sends a response message to the PC.
C1 C2 C3 C4 P1 P2 P3 P4
Command field
(4 prescribed
alphanumerical characters
Parameter field
(4 character string comprised of:
0-9, space, ?)
Example: VOLM030
* Be sure to input 4 characters for the parameter. Pad with
spaces (“
”) if necessary.
(“
” is a return code (0D
H
))
Wrong : VOLM30
Right : VOLM030
The current value can be returned by using “????” as the
parameter.
Example:
VOLM ? ? ? ?
From PC to monitor (How much
is current volume setting?).
30
From monitor to PC (Current
volume setting: 30).
n
Response code format
When a command has been executed correctly
O K
Return code
(0DH)
A response is returned after a command is executed.
When a command has not been executed
R R E
Return code
(0D
H)
TIPS
ERR is returned when there is no relevant command or
when the command cannot be used in the current state of
the monitor.
If communication has not been established for reasons
such as a bad connection between the PC and monitor,
nothing is returned (not even ERR).
ERR may be returned when a command cannot be
received correctly due to interference from the surrounding
environment.
Please ensure that the system or software retries the
command if this occurs.
n
Communication interval
After OK or ERR is returned, you must send the following
commands.
To set a timeout for the command response, specify 10
seconds or longer.
Provide an interval of 100 ms or more between the
command response and the transmission of the next
command.