Installation Manual RESU 10H DLT Type-C

12
2.1.2 Performance
Electrical Characteristics
Total Energy Capacity
9.8kWh@25°C (77°F), 100% State of Energy
Usable Energy Capacity
1)
9.3kWh
Battery Capacity
63 Ah
Voltage Range
Charge
Discharge
468 to 550 VDC
430 to 507 VDC
Absolute Max. Voltage
570VDC
Max. Charge/Discharge Current
10.7A@467V / 11.7A@427V
Max. Charge/Discharge Power
2)
5kW
Peak Power
3)
(only discharging)
7kW for 10 sec.
Peak Current (only discharging)
16.3A@430V for 10 sec.
Communication Interface
CAN
DC Disconnect
Circuit Breaker
Connection Method
Spring Type Connector
User interface
LEDs for Normal and Fault operation
Operating Conditions
Installation Location
Indoor / Outdoor (Wall-Mounted)
Operating Temperature
14 to 113°F (-10 to 45°C)
Operating Temperature (Recommended)
59 to 86°F (15 to 30°C)
Storage Temperature
-22 to 131°F (-30 to 55°C)
Humidity
5% to 95%
Altitude
Max. 6,562ft (2,000m)
Cooling Strategy
Natural Convection
Certification
Safety
Cell
Battery Pack
UL1642
UL1973 / CE / RCM / TUV(IEC 62619)
Emissions
FCC
Hazardous Materials Classification
Class 9
Transportation
UN38.3
Ingress Rating
IP55
Test Conditions - Temperature 25, at the beginning of life.
Energy is measured under specific condition from LGC (0.3CCCV/0.3CC).
1) Value for Battery Cell Only(Depth of Discharge 95%).
2) LG Chem recommends 2.1kW for maximum battery lifetime.
3) Peak Current excludes repeated short duration(less than 5 sec. of current pattern).