Installation Manual RESU 10H DLT Type-C

24
10. Connection Power / Communication cables,
according to the labels marked.
11. See 3.2.1. for Power Cable specifications
a) Connect the ground wire to terminal 1.
b) Connect the negative line of the power
cable to terminal 2.
c) Connect the positive line of the power
cable to terminal 3.
12. See 3.2.1. for Communication Cable
specifications
At first, connect the ground wire to terminal 2.
Then, make connections to the other terminals
one after another except terminal 6.
Leave terminal 6 unconnected.
Install protection cover before turning on.
13. Connecting the battery pack to the inverter
Refer to the installation instructions
for the inverter to connect the power cable
and communication cable to the inverter.
Then, push the circuit breaker switch up
so that it is in the ON position.