Installation Manual RESU 10H SEG Type-R

Installation
25
6. Hang the User Guide onto the latch
on the rear of the battery.
5. Close the wiring box cover.
Reattach battery over the two latches
on the rear.
Connect/disconnect the wire to connector sequence
CAUTION
Please turn on or off the switch by pushing the middle of the bar, where lever.
It is forbidden to push either end side of the bar. Any improper use could
damage the product.
1. Make sure the circuit breaker off and the
disconnect switch off.
If removing power cables, check for
voltage at power cable terminal
2. To remove one of the wires from its
terminal, insert a small screwdriver into
the rectangular hall above the terminal.
3. Apply slight pressure to the screwdriver
and at the same time pull out the wire.