Limited Warranty EU RESU 13

Attachment 1. Battery Technical Specifications
Table 1.1 Specification Overview of RESU13
Items
RESU13
Electrical
Cell
JH3
Nom. Voltage/ Operating Voltage
Range
51.8 V / 42 ~ 58.8V
Total Energy Capacity
13.048 kWh
Max. Power / Max. Current
5 kW / 119 A
Peak Power (for 3sec)
/ Peak Current (for 3sec)
7 kW / 166.7 A
Peak Current excludes repeated short duration (less than 3
sec.) of current pattern.
Peak Power for Backup Mode
11kW for 3sec
Standard
Charging
Condition
(CC)
Charging Current
56.7 A
Cut off condition
(58.8 V)
12.6A @ 58.8V, Ambient 25
Std.
Discharging
Condition
(CC)
Discharge Current
56.7 A
Cut off Condition
Discharge Cut off voltage : 42 V
Battery pack Round-trip Efficiency
>95% (under specific condition)
Communication Interface
CAN 2.0b Standard ID (500kbps)
DC Disconnect
Circuit Breaker, Contactor, Fuse
Environmental
Installation location
Indoor(Wall-mounted) / Outdoor (if installed outdoors, do
not allow the battery pack to be exposed to direct sunlight
and moisture)
Temperature
Operating Range
(Optimal Range)
-10 ~ 50
(15 ~ 30 )
Storage Range
a)
1) - 30 ~ 60 (acceptable for 7 days in total)
2) - 20 ~ 45 (acceptable for the first 6 months)
3) - 20 ~ 30 (acceptable for 7
th
month~12
th
month)
Operating Humidity Range
b)
5 ~ 95% RH, Non Condensing
Altitude
Max. 2,000m
Cooling Strategy
Natural convection
Reliability &
Certification
Safety
Cell
UL1642
Battery Pack
CE/ FCC / RCM / TUV (IEC 62619)
Hazardous Materials Classification
Class 9
Transportation
UN38.3 (UNDOT)
Ingress
IP55
a) Storage Temperature Range is temperature range during transporting and storing the Products until the installation
b) Storage Humidity is exactly same as Operating Humidity, and if it falls outside of the range, corrosion may occur or insulation
performance may be affected.