Service manual

MD-MT180
– 23 –
: Temp setting menu
: TEMP reference
: Reference
§ § : Temperature code
: TEMP A/D input value
: Measurement value
PLAY
T e m p
TEMP Setting
T M § §
T p i n
FAST FORWARD FAST REVERSE
* When the [STOP ] button is pressed in specific menu, the "TEST MODE STOP" state is set.
* When the [MENU] button operation is performed in the specific state, the menu changes to
"TEMP SETTING menu".
* In the specific state the setting changes in the range of "00h to FFh" when the
[VOL.+/] button is pressed.
* When the [ENTER] button is pressed in each state, the set digit is changed.
: Adjustment setting menu
PLAY
A D J S E T
Adjustment Setting
C O K
F A B
FAST FORWARD FAST REVERSE
H S G
FAST FORWARD FAST REVERSE
L S G
FAST FORWARD FAST REVERSE
* When the [STOP ] button is pressed in specific menu, the "TEST MODE STOP" state is set.
* When the [MENU] button operation is performed in the specific state, the menu changes to
"TEMP SETTING menu".
* In the specific setting display state the setting change digit changes when the [ENTER]
button is pressed.
1st digit (initial value) 2nd digit
ENTER
ENTER
* In the specific state the setting changes in the range of "0h to Fh" when the [VOL.+/]
button is pressed.
* When the [ENTER] button is pressed in each state, the set digit is changed.