Service manual

– 23 –
MD-X5H/CP-X5H
Step 1 Testmode STOP state [ t s m e ]
Step 2
Press the CD PLAY button four times.
RESULT menu [ _ R E S U L T _ _ _ ]
Step 3 Press once the MD PLAY button. Indication of set value [ H A G : _ _ _ ]
Step 4 Press once the CD PLAY button. Indication of set value [ H B G : _ _ _ ]
Step 5 Press once the CD PLAY button. Indication of set value [ L A G : _ _ _ ]
Step 6 Press once the CD PLAY button. Indication of set value [ L B G : _ _ _ ]
Step 7 Press once the CD PLAY button. Indication of set value [ P E G : _ _ _ ]
Step 8 Press once the CD PLAY button. Indication of set value [ P F G : _ _ _ ]
Step 9 Press once the CD PLAY button. Indication of set value [ G E G : _ _ _ ]
Step 10 Press once the CD PLAY button. Indication of set value [ G F G : _ _ _ ]
Step 11 Press once the CD PLAY button. Indication of set value [ G C G : _ _ _ _ ]
Step 12 Press once the MD STOP button. RESULT menu state [ _ R E S U L T _ _ _ ]
3. RESULT mode (final adjustment)
Step No.
Setting Method
Remarks Display
: Measurement value
• ressing the REC button causes reversing.
• If the VOL UP button is pressed while the set value is indicated, the set value increases, and the new set value is stored in RAM.
• If the VOL DOWN button is pressed while the set value is indicated, the set value reduces, and the new set value is stored in RAM.
• If the VOL UP/VOL DOWN button is held down, the set value changes continuously with 100 ms cycle.
• The digit of increase/decrease by the VOL UP/VOL DOWN button can be shifted with the aid of CD STOP button.
Step 1 Testmode STOP state [ t s m e ]
Step 2
Press the CD PLAY button five times.
MANUAL auxiliary adjustment mode [ _ M N U _ Y O B I _ ]
Step 3 Press once the MD PLAY button. Initial setting Temperature measuring mode [ T M P : _ _ _ _ ]
Step 4 Press once the CD PLAY button. Offset "0" setting A signal offset tentative measurement [ H A o : _ _ _ ]
Step 5 Press once the CD PLAY button. B signal offset tentative measurement [ H B o : _ _ _ ]
Step 6 Press once the CD PLAY button. E signal offset tentative measurement [ H E o : _ _ _ ]
Step 7 Press once the CD PLAY button. F signal offset tentative measurement [ H F o : _ _ _ ]
Step 8 Press once the CD PLAY button. Offset tentative measurement Laser ON [ L O N : _ _ _ _ _ _ ]
Step 9 Press once the CD PLAY button. Innermost periphery move RF side FG rough adjustment [ R F g : _ _ ]
Step 10 Press once the CD PLAY button. Focus ATT (A signal) tentative setting [ S A g : ]
Step 11 Press once the CD PLAY button. Focus ATT (B signal) tentative setting [ S B g : ]
Step 12 Press once the CD PLAY button. RF side pit section TG adjustment [ P T G : _ _ ]
Step 13 Press once the CD PLAY button. Pit section COUT level setting [ P C H : _ ]
Step 14 Press once the CD PLAY button. Outer periphery move RF side groove TG adjustment [ G T G : _ _ ]
Step 15 Press once the CD PLAY button. Groove section COUT level setting [ G C H : _ ]
Step 16 Press once the CD PLAY button. RF side TCRS adjustment [ R C G : _ _ ]
Step 17 Press once the CD PLAY button. Tracking ATT (E signal) setting [ S E G : ]
Step 18 Press once the CD PLAY button. Tracking ATT (F signal) setting [ S F G : ]
Step 19 Press once the CD PLAY button. Indication of tracking EFMIO measurement [ g M I : _ _ _ ]
Step 20 Press once the CD PLAY button. RF side pit section FG adjustment [R F G : _ _ ]
Step 21 Press once the CD PLAY button. Focus ATT (A signal) setting [ S A G : ]
Step 22 Press once the CD PLAY button. Focus ATT (B signal) setting [ S B G : ]
Step 23 Press once the CD PLAY button. Offset "0" setting A signal offset measurement [ H A O : _ _ _ ]
Step 24 Press once the CD PLAY button. B signal offset measurement [ H B O : _ _ _ ]
Step 25 Press once the CD PLAY button. E signal offset measurement [ H E O : _ _ _ ]
Step 26 Press once the CD PLAY button. F signal offset measurement [ H F O : _ _ _ ]
Step 27 Press once the CD PLAY button. TCRS signal offset measurement [ T C O : _ _ _ ]
Step 28 Press once the CD PLAY button. A signal offset measurement [ L A O : _ _ _ ]
Step 29 Press once the CD PLAY button. B signal offset measurement [ L B O : _ _ _ ]
Step 30 Press once the CD PLAY button. E signal offset measurement [ L E O : _ _ _ ]
Step 31 Press once the CD PLAY button. F signal offset measurement [ L F O : _ _ _ ]
5. MANUAL auxiliary adjustment mode (only low reflection disc)
Step No.
Setting Method
Remarks Display
: Measurement value, : Set value, : Account value