Owner`s manual

2 TASCAM MD-CD1MKIII
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK). NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol,
within equilateral triangle, is intended to
alert the user to the presence of uninsulated
dangerous voltage within the products
enclosure that may be of sufficient
magnitude to constitute a risk of electric
shock to persons.
The exclamation point within an equilateral
triangle is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
WARNING: TO PREVENT FIRE OR SHOCK
HAZARD, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
For U.S.A.
ª
TO THE USER
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user
will be required to correct the interference at his own
expense.
CAUTION
Changes or modifications to this equipment not expressly
approved by TEAC CORPORATION for compliance could
void the user's authority to operate this equipment.
CAUTIONS ABOUT LASER RADIATION
ª
This product has been designed and manufactured
according to FDA regulations “title 21, CFR, chapter 1,
subchapter J, based on the Radiation Control for Health
and Safety Act of 1968, and is classified as a class 1 laser
product. There is no hazardous invisible laser radiation
during operation because invisible laser radiation emitted
inside of this product is completely confined in the
protective housings.
The labels required in this regulation are shown at 1 and
2.
21503-W
1
2
Cautions:
DO NOT REMOVE THE PROTECTIVE HOUSING USING A
SCREWDRIVER.
USE OF CONTROLS OR ADJUSTMENTS OR
PERFORMANCE OF PROCEDURES OTHER THAN THOSE
SPECIFIED HEREIN MAY RESULT IN HAZARDOUS
RADIATION EXPOSURE.
IF THIS PRODUCT DEVELOPS TROUBLE, CONTACT YOUR
NEAREST QUALIFIED SERVICE PERSONNEL, AND DO
NOT USE THE PRODUCT IN ITS DAMAGED STATE.
CLASS 1M INVISIBLE LASER RADIATION WHEN OPEN
AND INTERLOCKS DEFEATED. DO NOT VIEW DIRECTLY
WITH OPTICAL INSTRUMENTS.
MD drive optical pickup:
Type : HPM-312S
Manufacturer : SHARP CORPORATION
Laser output : Playback 0.6 mW
Recording: According to TOC information.
(Approx. 4.5 mW on MMD-318)
Wavelength : 785 nm
Standard : IEC60825-1 Edidion 1.2-2001
CD drive optical pickup:
Type : SF-P151NVD
Manufacturer : Sanyo Electric Co,Ltd.
Laser output : Less Than 0.2 mW on the
objective lens
Wavelength : 790+10/–15 nm
Standard : IEC60825-1: 2007 / EN60825-1:2007
IMPORTANT SAFETY PRECAUTIONS