NUJD440

SIM02E-003A
4
INSTALLATION INSTRUCTIONS -PHOTOVOLTAIC MODULES-
1. INSTALLATION
Mounting Using Clips:
The PV modules can be mounted with clips (clamps)
as defined in the following. Note that the mounting clips
should meet the required dimensions as defined in the
Figure1. Note that the CLIP CENTER POSITION (e)
from the module corner should be located in the range
as specified in the Annex. All clips shall hold the module
frame completely within their width. Please be aware
that the module under heavy load would get serious
deflection which could cause cell cracks that affects
power degradation. The PV module must be supported
on the array system and must overlap the array rail by
at least 10 mm.
Mounting Using Frame Bolt Holes:
The modules may be fastened to a support using the
bolt holes in the bottom of the frames at any of locations
shown in Annex. The module should be fastened with
four (4) M8 bolts. Recommended torque is 12.5 Nm.
2. ELECTRICAL INSTALLATION INSTRUCTION
Cable caracteristics:
Conductor size: 4.0 mm
2
, Cable type: XLPE cable
(H1Z2Z2-K)
Maximum DC voltage: 1.5 kV
Ambient temperature: -40 °C to +90 °C
Maximum conductor temperature: 120 °C
PV module configuration (Recommend):
# Maximum series configuration: please refer to Table 1
# Maximum parallel configuration: (Parallel connection of
each string shall be conducted with following two options.
Any other parallel connections are prohibited.)
a) Case of using the diodes; 1 diode per maximum 2
parallel strings (Connect a diode or more in series for
every string or every 2 parallel strings for protection of
PV module from reverse current overload.)
b) Case of using the fuses; 1 fuse per every string (Connect
a fuse for every single string for protection of PV module
from reverse current overload.)
Connection cables requirement:
The PV module shall be mated to the same connectors;
Type: C1 (System voltage 1,500 V)
Brand: Solargiga Energy Holdings Limited
In case connectors will be replaced by qualified personnel
according the mounting instructions of the manufacturer of
the new connectors, the guarantees on the module itself,
will remain valid according the applicable terms.
3. WARNING
Keep all PV MODULES and
electriacal CONNECTORS clean &
dry before installation.
4. Disposal
Dispose PV modules properly. For
Information about the proper
disposal, contact your local
recycling site.
ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS
Rated electrical characteristics are within ±10 percent of the indicated values of Voc, Isc and +5/-0 percent of Pmax (power
measurement tolerance: ± 3 %), under STC (standard test conditions) (irradiance of 1000 W/m², AM 1.5 spectrum, and a cell
temperature of 25 °C (77 °F)).
T able-1. Electrical characteristics (at S T C )
Model
name
Maximum
Power
(Pmax )
Tolerance
Open-Curcuit
Voltage
(Voc)
Short-Circuit
Current
(Isc)
Voltage at point
of max . Power
(Vmpp)
Current at point
of max . Power
(Impp)
Maximum
system voltage
Over-Current
Protection
Class for protection
against elecrical
shock
Maximum series
configuration(*)
NU-JD440 440W +5%/-0% 49.77V 11.49A 41.20V 10.68A 1,500V 20A
25
* The maximum series number of modules depends on the local conditions. These values are calculated under the condition of Voc at -40 °C.
Under normal conditions, a PV module is likely to experience conditions that produce more current and/or voltage than reported
at Standard Test Conditions. Accordingly, the values of Isc and Voc marked on this PV module should be multiplied by a factor
of 1.25 when determining component voltage ratings, conductor capacities, fuse sizes and size of controls connected to the PV
module output.
The PV module has been qualified in an environmental temperature range of -40 °C to +40 °C and up to 100 % relative humidity
as well as rain, and the altitude up to 2,000 m in accordance with IEC61730.
Class for protection against electric shock
This PV module is classified as Class according to
IEC61730. These PV modules are intended for installation
where geeral user access and contact to insulated live parts is
anticipated.
FIRE RATING
This PV module is rated as “Fire safety class C” according to
IEC61730-2:2004 or UL790.
Figure1. Clips (Clamps) requirement
1) Clip: Al alloy, 3 mm Min. thickness
2) Catch length (50 mm Min.)
3) Covering depth (7 mm Min. on the frame)
4) Supporting depth (10 mm Min.)
5) Frame (applicable to all frame sections)
6) Array rail (applicable to parallel or crossed mounting)