Specifications
13
'SELECT
14
OV
15
NC
16
OV
17
FG
18
+5V
19
-
30
GND
31
PRIME
32 FAULT
33
av
34
IRT
35,36
NC
• (Note)
Conditions for
SELECT (ON-LINE)
• Signal to indicate whether the printer is in SELECT
or DESELECT mode. When the printer
is
in SELECT
mode (ON-LINE mdoe), data can be received.
• High level when the printer is in SELECT mode.
(Positive logic)
• PULL UP at
330n
• Twist pair, GND
• Printer reset signal (Negative logic)
(Note) IRT for terminal No.34 is also a printer reset
signal, bu t has an opposite logic. When one
reset signal
is
employed, the
other
signal shall
be
made
NC.
• Signal
to
indicate that the printer is in FAULT state.
(Negative logic)
• Conditions for FA
UL
T
• PE
•
Dese1ect
• Printer reset signal (Positive logic)
(Refer
to
terminal
No.3I.)
• When ON-LINE/OFF-LINE switch
is
pressed during DESELECT.
• When "DC I "
is
received.
• When
PE
Occurs.
•
If
the ON-LINE/OFF-LINE switch
is
pressed in
PE
state, the select state emerges to cancel PE,
I-line data
is
read and printed, and then OFF-Line state emerges again. Then, the SELECT signal
becomes
LOW.
(Override function)
Conditions for DESELECT
•
When
ON-LINE/OFF-LINE switch
is
pressed during SELECT.
•
When
"DC3"
code
is
received.
•
When
PE
occurs.
• When power source
is
turned on.
(This state can be altered by the operation
of
the internal function switch.)
• When
an
error occurs in the printer.
36