Specifications

104
4.10 Wall hanging metal fixture for the plasma display : PDK-4006
4.10.1 Specifications
Outer dimensions .............. 916 (W) × 125 (D) × 714 (H) mm
Weight ................................ 6.7 kg (metal fixture alone)
37.5 kg <38.3 kg> (metal fixture with two plasma displays PDP-V402 <PDP-V402E>)
Material .............................. Steel pipe for general structures (STK-MR)
Treatment ........................... Semi-matt black paint (Pioneer's original color)
Package dimensions .......... 885 (W) × 270 (D) × 80 (H) mm
Package weight ................. 7.6 kg
Accessories
Vertical frame .........................................................2 pcs (for the left side and the right side)
Lateral frame ..........................................................2 pcs
Hexagonal socket frange bolt.................................8 pcs
Monitor fixing bolt ..................................................4 pcs
Hexagonal wrench .................................................1 pc
How to mount standard optional items (PDK-4006)
The operating environmental temperature must be kept within the range of 0 to 35 °C when this fixture is used to
install the display. When the angle is 5 degrees or more, you may use the display at 0 to 40 °C. For details, see
“ 4.9.2 7), Recommended ambient operating temperature.”
Angle: less than 5°
Operate at 0 to 35 °C.
When PC75Hz is input, however, operate at
0 to 30°C.
(Do not cover the metal fixture or the sides
of the display main body.)
Angle: 5° or more
May be used between 0 to 40 °C.
When PC75Hz is input, however, operate at
0 to 35°C.
(Do not cover the metal fixture or the sides
of the display main body.)
• Recommended ambient operating temperature (in the open state)
Wall Wall
5° or more (117mm or more from Wall)
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
* When mounting the down converter (PDA-4003), the same working temperature conditions apply.
PC-9800 (56.4Hz)
PC-9800 (70.1Hz)
VIDEO Machintosh (66.7Hz)
VGA (60HZ)
VGA (72.8Hz, 75Hz)
Angle: Less than 5° 0~35 °C 0~35 °C 0~30 °C
Angle: Equal to or
0~40 °C 0~40 °C 0~35 °C
greater than 5°
Working temperature requirements