Specifications

180
RS-232C adjustment mode
5.4.4 List of GET commands
What are GET commands?
Commands to output adjustment data from the PC connected to the plasma display to another personal computer
Adjustment data is output for each input function, each input mode, and each mode.
Adjustment data is output in ASCII.
Note: Data in < > indicates a command name.
1) <GPS> (GET POSITION DATA) — Phase-adjustment data is output in the following format:
(1) STX (02H)
(2) Adjustment data for <CFR>/CLOCK FREQ (3BYTE).
(3) Adjustment data for <CPH>/CLOCK PHASE (3BYTE).
(4) Adjustment data for <HPS>/HOR.POSITION (3BYTE).
(5) Adjustment data for <VPS>/VER.POSITIOIN (3BYTE).
(6) ETX (03H)
Note:Not valid when VIDEO and Y/C are input.
2) <GWB> (GET W/B DATA) — Data for picture quality and white-balance are output in the following format:
(1) STX (02H)
(2) Adjustment data for <CNT>/CONTRAST (3BYTE).
(3) Adjustment data for <BRT>/BRIGHTNESS (3BYTE).
(4) Adjustment data for <COL>/COLOR (3BYTE). Note 1)
(5) Adjustment data for <TNT>/TINT (3BYTE). Note 1, 2)
(6) Adjustment data for <SHP>/SHARPNESS (3BYTE). Note 1)
(7) Adjustment data for <RHI>/RED HIGH-LIGHT (3BYTE).
(8) Adjustment data for <GHI>/GREEN HIGH-LIGHT (3BYTE).
(9) Adjustment data for <BHI>/BLUE HIGH-LIGHT (3BYTE).
(10)
Adjustment data for <RLW>/RED LOW-LIGHT (3BYTE).
(11)
Adjustment data for <GLW>/GREEN LOW-LIGHT (3BYTE).
(12)
Adjustment data for <BLW>/BLUE LOW-LIGHT (3BYTE).
(13)
ETX (03H)
Note: 1) When the input function is INPUT = RGB 1, 2, dummy data is output.
2) The dummy data is output when PAL signals are input for PDP-V402E.
3) <GST> (GET STATUS) — The status of each setting is output in the following format:
(1) STX (02X)
(2) PC software version (5 BYTE): Output by command name.
Example: 5559A: Indicates version A.
(3) Input function status (3 BYTE): Output by command name.
Example: IN1: Indicates VIDEO input.
(4) COLOR MODE Status (3 BYTE): Output by command name.
Example: CM1: COLOR MODE = 1.
(5) OSD indication, Enable/Disable setting state (3 BYTE): Output by command name.
Example: DIY: Indicate OSD indication and Enable.
(6) Remote control Enable/Disable status, and operation panel (3 BYTE): Output by command name.
Example: KLY: Indicates Operation Disabled.
(7) RGB2 priority mode setting state, (3 BYTE): Output by command name.
Example: A4N: Indicate RGB2 priority mode OFF.
(8) SCART RGB mode setting state, (3 BYTE): Output by command name.
Example: CNN: Indicate SCART RGB mode OFF.
(9) Hour meter value (5BYTE)
Example: 00020: Accumulated conduction time is 20 hours.
(
10
)ETX (03H)