Specifications

34
DRIVE THE MOTOR
36
Frequency jump 3B
0 to 590Hz,
9999
9999
37
Speed display
0, 1 to 9998
0
41
Up-to-frequency
sensitivity
0 to 100%
10%
42
Output frequency
detection
0 to 590Hz
6Hz
43
Output frequency
detection for reverse
rotation
0 to 590Hz,
9999
9999
44
Second acceleration/
deceleration time
0 to 3600s
5s
45
Second deceleration
time
0 to 3600s,
9999
9999
46
Second torque boost
0 to 30%, 9999
9999
47
Second V/F
(base frequency)
0 to 590Hz,
9999
9999
48
Second stall
prevention operation
level
0 to 400%
150%
49
Second stall
prevention operation
frequency
0 to 590Hz,
9999
0Hz
50
Second output
frequency detection
0 to 590Hz
30Hz
51
Second electronic
thermal O/L relay
0 to 500A,
9999
*2
9999
0 to 3600A,
9999
*3
52
Operation panel main
monitor selection
0, 5 to 14, 17 to
20, 22 to 35, 38,
40 to 45, 50 to
57, 61, 62, 64,
67, 87 to 98,
100
0
54
FM/CA terminal
function selection
*10
1 to 3, 5 to 14,
17, 18, 21, 24,
32 to 34, 50, 52,
53, 61, 62, 67,
70, 87 to 90, 92,
93, 95, 97, 98
1
55
Frequency
monitoring reference
0 to 590Hz
60/50Hz
*10
56
Current monitoring
reference
0 to 500A
*2
Rated
inverter
current
0 to 3600A
*3
57
Restart coasting time
0, 0.1 to 30s,
9999
9999
58
Restart cushion time
0 to 60s
1s
59
Remote function
selection
0 to 3, 11 to 13
0
60
Energy saving
control selection
0, 4, 9
0
61
Reference current
0 to 500A,
9999
*2
9999
0 to 3600A,
9999
*3
62
Reference value at
acceleration
0 to 400%, 9999
9999
63
Reference value at
deceleration
0 to 400%, 9999
9999
Parameter
Name Setting Range
Initial
Value
64
Starting frequency
for elevator mode
0 to 10Hz, 9999
9999
65
Retry selection
0 to 5
0
66
Stall prevention
operation reduction
starting frequency
0 to 590Hz
60/50Hz
*10
67
Number of retries at
fault occurrence
0 to 10,
101 to 110
0
68
Retry waiting time
0.1 to 600s
1s
69
Retry count display
erase
0
0
70 *
16
Special regenerative
brake duty
0 to 100%
0%
71
Applied motor
0 to 6, 13 to 16,
20, 23, 24, 30,
33, 34, 40, 43,
44, 50, 53, 54,
70, 73, 74, 330,
333, 334, 8090,
8093, 8094,
9090, 9093,
9094
0
72
PWM frequency
selection
0 to 15
*2
2
0 to 6, 25
*3
73
Analog input
selection
0 to 7, 10 to 17
1
74
Input filter time
constant
0 to 8
1
75
Reset selection/
disconnected PU
detection/PU stop
selection
0 to 3,
14 to 17
*2
14
0 to 3, 14 to 17,
100 to 103,
114 to 117
*3
76
Fault code output
selection
0 to 2
0
77
Parameter write
selection
0 to 2
0
78
Reverse rotation
prevention selection
0 to 2
0
79
Operation mode
selection
0 to 4, 6, 7
0
80
Motor capacity
0.4 to 55kW,
9999
*2
9999
0 to 3600kW,
9999
*3
81
Number of motor
poles
2, 4, 6, 8, 10,
12, 9999
9999
82
Motor excitation
current
0 to 500A,
9999
*2
9999
0 to 3600A,
9999
*3
83
Rated motor voltage
0 to 1000V
200/400V
*7
84
Rated motor
frequency
10 to 400Hz,
9999
9999
Parameter
Name Setting Range
Initial
Value
SimpleSimpleSimple
*2
For FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower
*3
For FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher
*7
Differs according to the voltage class. (200V class/400V class)
*10
Differs according to types. (FM type/CA type)
*16
Setting available for standard models only.