Specifications

72
Cable Part Number Connector A Cable Type Cable Length Connector B
Cable Part Number Connector A Cable Type Cable Length Connector B
Cable Type:
Type M 5 mm, low noise, shielded coaxi-
al cable is thicker and more
rugged. The 5 mm cable is
often specified for pilot and
process installations.
Type Z 6 mm, low noise, shielded tri-
axial cable is jacketed with an
extra lead for connecting solu-
tion ground to differential
input style transmitters.
How to Order
Custom Cables
Ask for the Custom Cable Worksheet to
specify custom cable assembly require-
ments. Return it by fax or mail to receive
a quotation within 24
hours.
Cables ar
e tagged with replacement part
numbers to enhance field serviceability.
Cable assemblies are 100% tested for
continuity, polarity, and the absence
of short circuits.
New & Improved pH Cable Assemblies
for K9 Metric Caps
Stock Cable Assemblies for
All F-695 FermProbe
®
pH Electrodes
The BioProcess Technologies® Catalog offers a wide
range of cable assemblies to connect FermProbe pH
electrodes with all of t odays pH transmi tters and
benchtop controllers.
Cables with the KP electrode plug fit on all brands
of pH electrodes that use the K9 cap.
The cables and electrodes are color coordinated so
that the orange KP electrode plug will connect to
the orange K9 cap on the pH electrode.
Choice of rugged 5 mm or 6 mm low noise coaxial
cable.
AX-1000-KP-M03DN KP plug M 3 ft (1 m) DIN plug
AX-1000-KP-M06DN KP plug M 6 f t (2 m) DIN plug
AX-1000-KP-M10DN KP plug M 10 ft (3 m) DIN plug
KP Electrode Plug to DIN 19262 Plug
Rugged 5 mm cable
AX-1000-KP-M03BC KP plug M 3 ft (1 m) BNC plug
AX-1000-KP-M06BC KP plug M 6 ft (2 m) BNC plug
AX-1000-KP-M10BC KP plug M 10 ft (3 m) BNC plug
KP Electrode Plug to BNC Plug
Rugged 5 mm cable
Connects to most NBS and Applikon vessel controllers
o r d e r i n g i n f o r m a t i o n
KP Electrode Plug BNC Plug
KP Electrode Plug DIN 19262 Plug
A B
A B
ables Cables Cables Cables Cables Cables Cables Cables Cables C
How to Convert Cables with a
KP Electrode Plug to Work
with the F-635 FermProbe
®
pH Electrodes
&
&
T I P S H I N T S
T I P S H I N T S
E-1245
Adapter
Step 1:
Thread the
adapter into an
AK9 cable plug.
Step 2:
Adapter and cable
are now converted
to work with the
FermProbe pH
electrode
disconnect cap.
E-1245 Adapter
Part Number:
E-1245-AAD-DZ
Stock cable assemblies feature the most commonly requested
cable lengths and connector schemes.
Broadley-James Corporation (U.S. & Canada) Toll-Free: 800-288-2833 E-mail: sales@broadleyjames.com
C
M
Y
CM
MY
CY
CMY
K