RESU Salesbook

Electrical Characteristics
Total
Energy Capacity
1)
9.8
kWh @25
°
C (77
°
F), Beginning of Life
Usable
Energy Capacity
1)
9.3 kWh
@25
°
C (77
°
F)
Battery Capacity
63 Ah
Voltage Range
Charge
468 to 550 V
DC
Discharge
430 to 507 V
DC
Absolute Max. Voltage
570 V
DC
Max. Charge/Discharge Current
10.7A@467V
/ 11.7A@427V
Max. Charge/Discharge
Power
2)
5kW
Peak
Power (only discharging)
3)
7kW for 10 sec.
Peak Current (only discharging)
16.3A@430V
for 10 sec.
Communication Interface
CAN
DC Disconnect
Circuit
Breaker, 25A, 600V rating
Connection Method
Spring Type Connector
User interface
LEDs for Normal and Fault operation
Operating Conditions
Installation Location
Indoor
/ Outdoor (Wall-Mounted)
Operating Temperature
14
to 113
°
F (-10 to 45
°
C)
Operating Temperature (Recommended)
59
to 86
°
F (15 to 30
°
C)
Storage Temperature
-
22 to 131
°
F (-30 to 55
°
C)
Humidity
5%
to 95%
Altitude
Max. 6,562ft (2,000m)
Cooling Strategy
Natural Convection
Noise Emission
< 40
dBA
Certification
Safety
Cell
UL1642
Battery Pack
UL1973 / CE / RCM / TUV (IEC 62619)
Emissions
FCC
Hazardous Materials Classification
Class 9
Transportation
UN38.3 (UNDOT)
Ingress Rating
IP55
Test Conditions - Temperature 25°C, at the beginning of life
Total Energy is measured under specific condition from LGC(0.3CCCV/0.3CC)
1) Value for Battery Cell Only (Depth of Discharge 95%). Actual usable energy at the AC output may vary
by condition, such as battery converter, inverter efficiency and temperature.
2) LG Chem recommends 3.3kW for maximum battery lifetime
3) Peak Current excludes repeated short duration (less than 10 sec. of current pattern).
6.2.4 RESU10H_ Type-C (v4.2)
- 30 / 37 -
6.2 RESU HV (400V)
6. Datasheet