RESU Salesbook

2. Compatible Inverter List
2.2 Compatible storage Inverters with RESU HV (v1.5)
Only compatible with the software versions which are mentioned above. More compatible inverters will be added.
All RESU installations require a compatible inverter.
Using a non-approved inverter will void the warranty provided by LG Chem.
See below important instructions when installing and using RESU HV.
1) Battery/Hybrid inverters should operate in On-Grid only. (Not in Off-Grid)
2) For On-Grid applications where Back-up mode may be sometimes utilized, the backed up circuits and inverters AC draw must not
exceed the battery current limit specifications.
Inverter Battery
Remark
Brand Model
Software Version*
RESU7H RESU10H
Type C
Type R
Type C
Type R
Sunny Boy Storage 2.5
2.04.24.R
or above
-
Cannot use in Back-up Mode
Sunny Boy Storage 3.7
Sunny Boy Storage 5.0
Sunny Boy Storage 6.0
1.50.14.R or above
-
Can use in Back-up Mode
- SPS(Secure Power Supply) mode is
supported
Sunny Boy Storage 3.8
US
Sunny Boy Storage 5.0
US
Sunny Boy Storage 6.0
US
1.50.14.R or above
-
Can use in Back-up Mode
- SPS(Secure Power Supply) mode is
supported
SE5000
-RWS / SE6000-RWS (EU)
3.2468 or above
-
Can use in Back-up Mode
-
RESU10H can be expanded up to
2 units
SE7600A
-USS2 / SE3800A-USS2 (US)
SE5000
-RWS2 / SE6000-RWS2 (EU)
SE5000
-AUS2 / SE6000-AUS2 (AU)
SE2000H ~ SE10000H with SESTI
-S4
-
Can use in AC coupled
-
Cannot use in Back-up Mode
Symo
Hybrid 3.0-3-S
Symo
Hybrid 4.0-3-S
Symo
Hybrid 5.0-3-S
1.11.3
-2 or above
-
Cannot use in Back-up Mode
SUN2000L
- 2KTL (EU/AU)
SUN2000L
- 3KTL (EU/AU)
SUN2000L
- 3.68KTL (EU/AU)
SUN2000L
- 4KTL (EU/AU)
SUN2000L
- 4.6KTL (EU/AU)
SUN2000L
- 5KTL (EU/AU)
V100R001C00SPC
329
o
r above
-
In case of RESU10H,
Charge/Discharge Power is limited
to 3.5kW
SUN2000
-3.8KTL-USL0 (NA)
SUN2000
-5KTL-USL0 (NA)
V100R001C10SPC
107 or
above
-
Can use in Back-up Mode only
with
PV in operation under rated power
-
In case of RESU10H,
Charge/Discharge Power is limited
to 3.5kW
SUN2000
-7.6KTL-USL0 (NA)
SUN2000
-9KTL-USL0 (NA)
SUN2000
-10KTL-USL0 (NA)
SUN2000
-11.4KTL-USL0 (NA)
-
Can use in Back-up Mode only
with
PV in operation under rated power
Nov. 2019
- 8 / 37 -