PRODUCT BOOK : Essential Information for RESU LV / HV 19th Nov, ’19 (V1.
LG Chem RESU Product Guide 2019.11.19 Rev Date Writer Version1.4 2019.07.09 Max Im Version1.5 2019.11.19 Jenny Hwang Updates RESU Supply Availability Notification Letter added Introduction for RESU10M added RESU LV Compatible Inverter List updated (to ver8.0) RESU HV Compatible Inverter List updated (to ver1.4) RESU HV Deep Discharge Issue Solved added Deep Discharged Battery & Charging Caution Letter updated RESU HV Forced Charging Process added RESU LV Compatible Inverter List updated (to ver8.
About this product book This product book includes essential information for RESU Low Voltage (LV) and High Voltage (HV) battery products. The information included in this product book is accurate at the time of publication. However, the product specifications are subject to change without prior notice. If changes occur, LG Chem will share the updated product book to our RESU Partners.
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04 0.0 Document revision history 0.1 About this product book 0.2 Contents 1. Introduction for RESU new products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06 1.1 RESU10M Introduction 2. Compatible Inverter List . . . . . . . . . . . . . . . . . . .
1. Introduction for RESU new products 1.
2. Compatible Inverter List 2.1 Compatible storage Inverters with RESU LV (v8.21) All RESU installations require a compatible inverter. Using a non-approved inverter will void the warranty provided by LG Chem. See below important instructions when installing and using RESU LV. 1) Battery inverters should operate in On-Grid only.
2. Compatible Inverter List 2.1 Compatible storage Inverters with RESU LV (v8.21) All RESU installations require a compatible inverter. Using a non-approved inverter will void the warranty provided by LG Chem. See below important instructions when installing and using RESU LV. 1) Battery inverters should operate in On-Grid only.
2. Compatible Inverter List 2.2 Compatible storage Inverters with RESU HV (v1.5) All RESU installations require a compatible inverter. Using a non-approved inverter will void the warranty provided by LG Chem. See below important instructions when installing and using RESU HV. 1) Battery/Hybrid inverters should operate in On-Grid only.
2. Compatible Inverter List 2.3 Compatible storage Inverters with RESU Modular (v1.0) All RESU installations require a compatible inverter. Using a non-approved inverter will void the warranty provided by LG Chem. See below important instructions when installing and using RESU Modular. 1) Battery/Hybrid inverters should operate in On-Grid only.
3.
4. Deep Discharged Battery & Charging Caution Letter Introduction This guide covers units with the AUX switch, before Disconnect Switch is applied, with production serial numbers in the table below. Product (Type-R) Production Before Battery Serial No. Before RESU10H September 17th 2018 R15563P3SSEG11809179045 RESU7H September 19th 2018 R11163P3SSEG11809199001 ※ For Europe region, Disconnect switch is applied to RESU HV(Type-R) models based on manufacturing date written below.
4. Deep Discharged Battery & Charging Caution Letter Instructions to prevent deep discharged battery To prevent deep discharged battery, when the RESU battery is not in use after installation, please turn off the Circuit Breaker(CB) first and then be sure to turn the AUX POWER switch off afterwards. Even if the Circuit Breaker(CB) is automatically tripped, the AUX POWER switch must be turned off manually.
4. Deep Discharged Battery & Charging Caution Letter LG Chem guideline for charging battery •Manual charge is possible for the RESU HV batteries only if the measured voltage is higher than the values mentioned in the table below. RESU7H 60V RESU10H 84V •LG Chem requires suitably qualified electricians to be trained with use of the battery charger prior to performing manually charging of RESUs and follow our strict procedures. > Please contact LG Chem prior to any manually charging of a RESU battery.
5. Introduction for RESU HV Forced Charging Process Purpose Forced (external) charging of RESU HV (“High Voltage”) batteries requires upfront training. LG Chem offers the necessary training through an online process. This documents describes the defined process. It is meant to support the maintenance of the required resources and to document changes made after the initial establishment. The objective is to restrict the access to high voltage chargers to trained personnel.
6. Datasheet 6.1 RESU LV (48V) 6.1.1 RESU3.3 (v1.9) Features RESU3.3 battery pack, designed for photovoltaic systems, can be easily connected with other models to expand its energy capacity. With RESU Plus, RESU3.3/6.5/10 can be “cross-connected” with each other. ※ RESU Plus is an expansion kit specially designed for 48V models.
6. Datasheet 6.1 RESU LV (48V) 6.1.1 RESU3.3 (v1.9) Electrical Characteristics Total Energy Capacity Usable Energy Capacity1) Battery Capacity Voltage Range Nominal Voltage Max. Charge/Discharge Current Peak Current2) Max. Charge/Discharge Power3) Peak Power2) Battery Pack Round-Trip Efficiency Communication Interface DC Disconnect 3.3 kWh 2.9 kWh 63 Ah 42.0 to 58.8 V DC 51.8 V DC 71.4A 78.6A for 3 sec. 3.0kW 3.3kW for 3 sec. >95% (under specific condition) CAN 2.
6. Datasheet 6.1 RESU LV (48V) 6.1.2 RESU6.5 (v2.6) Features RESU6.5 battery pack, designed for photovoltaic systems, can be easily connected with other models to expand its energy capacity. With RESU Plus, RESU3.3/6.5/10 can be “cross-connected” with each other. ※ RESU Plus is an expansion kit specially designed for 48V models.
6. Datasheet 6.1 RESU LV (48V) 6.1.2 RESU6.5 (v2.6) Electrical Characteristics Total Energy Capacity Usable Energy Capacity1) Battery Capacity Voltage Range Nominal Voltage Max. Charge/Discharge Current Peak Current2) Max. Charge/Discharge Power3) Peak Power2) Battery Pack Round-Trip Efficiency Communication Interface DC Disconnect 6.5 kWh 5.9 kWh 126 Ah 42.0 to 58.8 V DC 51.8 V DC 100A 109.5A for 3 sec. 4.2kW 4.6kW for 3 sec. >95% (under specific condition) CAN 2.
6. Datasheet 6.1 RESU LV (48V) 6.1.3 RESU10 (v1.5) Features RESU10 battery pack, designed for photovoltaic systems, can be easily connected with other models to expand its energy capacity. With RESU Plus, RESU3.3/6.5/10 can be “cross-connected” with each other. ※ RESU Plus is an expansion kit specially designed for 48V models.
6. Datasheet 6.1 RESU LV (48V) 6.1.3 RESU10 (v1.5) Electrical Characteristics Total Energy Capacity Usable Energy Capacity1) Battery Capacity Voltage Range Nominal Voltage Max. Charge/Discharge Current Peak Current2) Max. Charge/Discharge Power3) Peak Power2) Battery Pack Round-Trip Efficiency Communication Interface DC Disconnect 9.8 kWh 8.8 kWh 189 Ah 42.0 to 58.8 V DC 51.8 V DC 119A 166.7A for 3 sec. 5.0kW 7.0kW for 3 sec. >95% (under specific condition) CAN 2.
6. Datasheet 6.1 RESU LV (48V) 6.1.4 RESU13 (v1.1) Features RESU13 battery pack, designed for photovoltaic systems, can be easily connected with other models to expand its energy capacity. With RESU Plus, RESU13 can be connected only with another RESU13. ※ RESU Plus is an expansion kit specially designed for 48V models.
6. Datasheet 6.1 RESU LV (48V) 6.1.4 RESU13 (v1.1) Electrical Characteristics Total Energy Capacity Usable Energy Capacity1) Battery Capacity Voltage Range Nominal Voltage Max. Charge/Discharge Current Peak Current2) Max. Charge/Discharge Power Peak Power2) Peak Power for backup mode Battery Pack Round-Trip Efficiency Communication Interface DC Disconnect 13.1 kWh 12.4 kWh 252 Ah 42.0 to 58.8 V DC 51.8 V DC 119A 166.7A for 3 sec. 5.0kW 7.0kW for 3 sec. 11.0kW for 3 sec.
6. Datasheet 6.2 RESU HV (400V) 6.2.1 RESU7H _ Type-R (v4.2) Features Emergency Power Back-up Compact size and space saving Wide range of inverters available for matching Wall mounting installation Proven safety and 10 year warranty 53mm (2.1’’) 692mm (27.2’’) 569mm (22.1”) 660mm 569 (26.0”) 744mm (29.3’’) 206mm (8.1’’) Mechanical Characteristics Dimensions Weight Width Height Depth 744 mm (29.3’’) 692 mm (27.2’’) 206 mm ( 8.1’’) 75kg (165.
6. Datasheet 6.2 RESU HV (400V) 6.2.1 RESU7H _ Type-R (v4.2) Electrical Characteristics Total Energy Capacity 1) Usable Energy Capacity 1) Battery Capacity Voltage Range Charge Discharge Absolute Max. Voltage Max. Charge/Discharge Current Max. Charge/Discharge Power 2) Peak Power (only discharging) 3) Peak Current (only discharging) Communication Interface DC Disconnect Connection Method User interface 7.0 kWh @25°C (77°F), Beginning of Life 6.
6. Datasheet 6.2 RESU HV (400V) 6.2.2 RESU7H_ Type-C (v4.2) Features Emergency Power Back-up Compact size and space saving Matched with SMA Sunny Boy Storage models Wall mounting installation Proven safety and 10 year warranty 53mm (2.1’’) 907mm (35.7’’) 569mm (22.1”) 660mm 569 (26.0”) 744mm (29.3’’) 206mm (8.1’’) Mechanical Characteristics Dimensions Weight Width Height Depth 744mm (29.3’’) 907mm (35.7’’) 206mm ( 8.1’’) 87kg (191.
6. Datasheet 6.2 RESU HV (400V) 6.2.2 RESU7H_ Type-C (v4.2) Electrical Characteristics Total Energy Capacity 1) Usable Energy Capacity 1) Battery Capacity Voltage Range Charge Discharge Absolute Max. Voltage Max. Charge/Discharge Current Max. Charge/Discharge Power 2) Peak Power (only discharging) 3) Peak Current (only discharging) Communication Interface DC Disconnect Connection Method User interface 7.0 kWh @25°C (77°F), Beginning of Life 6.
6. Datasheet 6.2 RESU HV (400V) 6.2.3 RESU10H_ Type-R (v4.2) Features Emergency Power Back-up Compact size and space saving Wide range of inverters available for matching Wall mounting installation Proven safety and 10 year warranty 53mm (2.1’’) 907mm (35.7’’) 569mm (22.1”) 660mm 569 (26.0”) 744mm (29.3’’) 206mm (8.1’’) Mechanical Characteristics Dimensions Weight Width Height Depth 744 mm (29.3’’) 907 mm (35.7’’) 206 mm ( 8.
6. Datasheet 6.2 RESU HV (400V) 6.2.3 RESU10H_ Type-R (v4.2) Electrical Characteristics Total Energy Capacity 1) Usable Energy Capacity 1) Battery Capacity Voltage Range Charge Discharge Absolute Max. Voltage Max. Charge/Discharge Current Max. Charge/Discharge Power 2) Peak Power (only discharging) 3) Peak Current (only discharging) Communication Interface DC Disconnect Connection Method User interface 9.8 kWh @25°C (77°F), Beginning of Life 9.
6. Datasheet 6.2 RESU HV (400V) 6.2.4 RESU10H_ Type-C (v4.2) Features Emergency Power Back-up Compact size and space saving Matched with SMA Sunny Boy Storage models Wall mounting installation Proven safety and 10 year warranty 53mm (2.1’’) 907mm (35.7’’) 569mm (22.1”) 660mm 569 (26.0”) 744mm (29.3’’) 206mm (8.1’’) Mechanical Characteristics Dimensions Weight Width Height Depth 744 mm (29.3’’) 907 mm (35.7’’) 206 mm ( 8.1’’) 99.
6. Datasheet 6.2 RESU HV (400V) 6.2.4 RESU10H_ Type-C (v4.2) Electrical Characteristics Total Energy Capacity 1) Usable Energy Capacity 1) Battery Capacity Voltage Range Charge Discharge Absolute Max. Voltage Max. Charge/Discharge Current Max. Charge/Discharge Power 2) Peak Power (only discharging) 3) Peak Current (only discharging) Communication Interface DC Disconnect Connection Method User interface 9.8 kWh @25°C (77°F), Beginning of Life 9.
7. Appendix Do Not Publish 7.1 RESU Pack System Checks_RESU10H Type-R (HV) Sect. 1 Tools - Tools must have insulated grips. - Tools should have minimal exposed metal. • Socket wrench & 10mm nut • Insulation shoes • Insulation gloves - Insulation tape should be attached on the exposed metal of the tools. • Voltmeter • Insulation Tape RESU10H pack voltage must remain above > 84V in orde r to remain in operation or in the field.
7. Appendix Do Not Publish 7.1 RESU Pack System Checks_RESU10H Type-R (HV) Sect. 2 1) Disassemble RESU10H (Type-R) Carefully remove the top cover by prying the black casing at the rear corners Warning 1. Before opening the top cover of battery, please make sure to check the following: - 2. 2) The battery must be disconnected from the inverter. Battery circuit breaker(also the AUX power or DS switch ) is in OFF position. Wear Insulation gloves when disassembling the battery.
7. Appendix 7.1 RESU Pack System Checks_RESU10H Type-R (HV) Sect. 2 3) Do Not Publish Disassemble RESU10H (Type-R) Disassemble the power cable (plug-in connector) from the DC/DC converter Caution After disconnecting power cable, attach insulation tape on the power cable connector to prevent shorting.
7. Appendix 7.1 RESU Pack System Checks_RESU10H Type-R (HV) Sect. 3 A. Check Battery Pack Voltage Auxiliary Switch Warning Use caution to avoid shorting when (+) / (-) terminals are exposed. B. Disconnect Switch - PROBE SETUP: set voltmeter to DC volts. Negative probe at fuse RESU10H pack voltage must remain above > 84V in orde r to remain in operation or in the field.
7. Appendix 7.
7. Appendix 7.2 Check Fuse_RESU10H Type-R & Type-C (HV) Check Fuse Caution After disconnecting power cable, attach insulation tape on the power cable connector to prevent shorting.