Multi Display Setup Manual 2010/09/30 Business Solutions Equipment Division Business Solutions Dept.
About the handling of this material / Contents CONFIDENTIAL Contents Handling this material 1. 1. Precautions Precautions of of installation installation and and handling handling ‐ This document is made to explain the installation know‐how of large size display for our business partners. Hence, please handle this material very carefully. 2. 2.
CONFIDENTIAL Precautions of installation and handling (1) Precautions for Installation and moving Display surface Perspective drawing of the rear side view Grip Points The display surface is made of glass. Please use rear handgrip or handle by the edge of the display while installing and moving. It is possible to cause damage and malfunction of display. Please don’t apply physical pressure to the bezel such as bending or pulling on the bezel.
CONFIDENTIAL Precautions of installation and handling (2) Overall precaution and handling ‐ Do not use the information display under following conditions ; 1) Usage beyond its capability, feature/function, accuracy/precision 2) Usage that could develop into injury or life‐threatening situation under product breakdown 3) Usage that could lead to major monetary damage We will not take any responsibility if the product was used under above conditions.
CONFIDENTIAL Mechanical installation (Optional Interface board) Optional Interface board PN‐ZB02 ■Installation Procedure PN‐V601 has following input/output terminals. Additional terminals such as DVI‐D input/output, Component, LAN etc.. are available by attaching the optional expansion board PN‐ZB02. CONFIDENTIAL 4 Multi Display Setup Manual September.
Mechanical installation (Remote Control kit) CONFIDENTIAL How to attach Remote Control All monitors can be operated using one remote controller when one of the monitors is fitted with a remote control sensor box CONFIDENTIAL 5 Multi Display Setup Manual September.
Setting for Remote Control (1) CONFIDENTIAL Setting for Remote Control kit CONFIDENTIAL 6 Multi Display Setup Manual September.
Setting for Remote Control (2) CONFIDENTIAL 7 CONFIDENTIAL Multi Display Setup Manual September.
CONFIDENTIAL Basic display method (Enlarge or Dot by Dot) Resolution for Enlarge mode and Dot by Dot configuration Dot‐by‐dot mode 2304 1x3 Enlarge mode Create contents with 2304x1366 pixels (or 16:9.5 aspect ratio under dot‐by‐dot)* 1366 The enlarge mode in this this configuration won’t work because aspect ratio will be different from original the one. 2732 2x2 Create contents with 2732x1536 pixels (or 16:9 aspect ratio under dot‐by‐dot)* 1536 Enlarge 1920x1080 contents to 2732x1536.
CONFIDENTIAL Cable routing (for Enlarge mode) Cable configuration for Enlarge mode 1) DVI Daisy chain 2) Other input (HDMI/RGB/Component) and DVI connection in case of more than 6 monitors. Third monitor and after Signal Splitter DVD/BLUE RAY Player Please refer to the user manual for detailed connection information of the signal splitters. CONFIDENTIAL 9 Multi Display Setup Manual September.
CONFIDENTIAL Enlarge mode setup Enlarge mode setup with OSD CONFIDENTIAL 10 Multi Display Setup Manual September.
Cable routing (for Dot by Dot configuration) CONFIDENTIAL Cabling for Dot by Dot DVI / HDMI DVI / HDMI Work station PN-V601 PN-ZB02 PN-V601 PN-ZB02 Graphic board PN-V601 PN-ZB02 PN-V601 PN-ZB02 DVI / HDMI DVI / HDMI Graphic boards which have multiple out put terminals are necessary to realize dot by dot display. Each monitor needs to be connected via DVI or HDMI to a dedicated port on the graphic cards. Multi display setup depends on the type of graphic board and graphics driver.
Cable routing for monitor control Cabling (for monitor control) Three types of connections are available. 1) Connection by RS‐232C PNZR01(light receiving device) (1) Control and measuring PC CONFIDENTIAL 1. Choose RS‐232C from RS‐232C/LAN SELECT at the set up page of the all monitors in OSD menu 2. Assign a unique ID number to each monitor 3. Connect PC (1) and the first monitor with RS‐232C straight cable (do not use a null‐modem cable) 4. Make a daisy chain with RS‐232C straight cables 5.
Monitor control software setup CONFIDENTIAL Monitor control with calibration tool CONFIDENTIAL 13 Multi Display Setup Manual September.
Monitor control software setup CONFIDENTIAL Monitor control with calibration tool The parameters are different depending on the particular connection 1) Connection by RS‐232C Search Interface : All Search daisy chained monitors: check 2) Connection by LAN Search Interface : LAN Search daisy chained monitors: uncheck 3) Mixed connection by LAN and RS‐232C Search Interface : All Search daisy chained monitors: check CONFIDENTIAL 14 Multi Display Setup Manual September.
Calibration tool software setup CONFIDENTIAL Setting Video Wall and Enlarge mode via the calibration tool CONFIDENTIAL 15 Multi Display Setup Manual September.
CONFIDENTIAL Calibration (1) How to adjust the color •The color can be adjusted by the image adjustment function of the display by operating remote controller or the control tool offered from our company. (Please refer to software tool SHARP Monitor Control Software. ) • Also, it can be adjusted with the color calibration tool from our company. (Please refer to software tool Multi Display Calibration Tool). It is necessary to buy our recommended colorimeter.
CONFIDENTIAL Calibration (2) color adjustment procedures for difference of the color temperature and brightness between displays due to change over time color adjustment procedures when display is replaced Confirm the difference of color and brightness by eye between replaced display and other ones No difference Select a display and measure targeted color and brightness with the color calibration tool End of Adjustment Adjust with the image adjustment function of the display Can adjust Can adjust a
CONFIDENTIAL Calibration (3) How to implement calibration CONFIDENTIAL 18 Multi Display Setup Manual September.
CONFIDENTIAL Calibration (4) How to implement calibration CONFIDENTIAL 19 Multi Display Setup Manual September.
CONFIDENTIAL Calibration (5) How to implement calibration CONFIDENTIAL 20 Multi Display Setup Manual September.
Tools for supporting installation (1) CONFIDENTIAL Installation tools for attachment and moving to the installation location Installation handle Installation eyebolt device Interlocking pipe Please take care not to add pressure to parts other than the ones marked with a heavy line in the diagram during installation and maintenance. If pressure is added to other parts, the display itself may be distorted or damaged. Support PN-V601 by holding both corners.
Tools for supporting installation (2) CONFIDENTIAL We will provide following service parts for installation (they are subject to fees) Name (temporary) Use Image Installation handle (UKOG1005MPZZ) ‐ For lifting the PN‐V601 up to a high location This device is inserted into holes on top of PN‐V601 and enable lifting the PN‐V601 up to a high location during installation. 2 pieces of this device are necessary per one PN‐V601. This installation handle is for improving efficiency of installation.
Tools for supporting installation (3) CONFIDENTIAL We will provide following service parts for installation (they are subject to fees) Name (temporary) Use Image Protection cover for the corner of display (UKOG1008MPZZ) ‐‐ Reduce shock while moving and installing These covers are attached on the two bottom corners of PN‐V601 to protect PN‐V601 from shock. It is easy to remove the cover. ‐ 2 units of this cover are necessary per one PN‐V601.
CONFIDENTIAL Tools for supporting installation (4) We will provide following service parts for installation (they are subject to fees) Name (temporary) Use Image Installation spacer device (UKOG1011MPZZ) ‐ Insert this spacer between the PN‐V601 while installing the neighboring PN‐V601s so the units do not touch. And after installation is finished, remove this spacer device.
Tools for supporting installation (5) Tentative name Bezel sheet Use CONFIDENTIAL Figure Image ‐Please attach bezel sheets on the 4 sides of the PN‐V601 to cover the white areas on the sides of the display. ‐4 bezel sheets is necessary per one PN‐V601(for top / bottom / right / left side). ‐In order to study the detail on how to attach bezel sheet, please refer to the introduction material enclosed in PN‐V601 package (one sheet).