Operating instructions

28
Models C709 & C717Important: To the Operator
081111
Listed below are variable failure code messages
which could appear on line 2.
HT Heat Time Too Long
Mix temperature did not rise above 151°F
(66.1°C) in less than 90 minutes.
CL Cool Time Too Long
Mix temperature in the hopper and freezing
cylinder did not fall below 41°F (5°C) in less
than 120 minutes.
TT Total Time Too Long
The heat treatment cycle must be completed
in no more than 4 hours.
MO Mix Out Condition
A mix out condition was detected at the start
or during the heat cycle.
ML Mix Low Condition
The Heat Phase or Cool Phase time was
exceeded and a mix low condition was
present.
BO Beater Overload Condition
A beater overload occurred during the heat
cycle.
HO High Pressure Cut-Out Condition
A high pressure cut-out condition occurred
during the heat cycle.
PF Power Failure
A power failure caused the Heat Phase,
Cool Phase, or Total Cycle Time to exceed
the maximum allowed time. If a power failure
occurs, but the heat treatment cycle does
not fail, an asterisk(*) will appear on the third
line of the display.
PS Power Switch OFF
The power switch was placed into the OFF
position during the heat cycle.
TH Thermistor Switch OFF
A thermistor probe has failed.
RC Record Cleared
Data has not been written to the page or
cleared due to corrupt data.
OP Operator Abort
Indicates the heat cycle was aborted in the
OPERATOR ABORT option in the Service
Menu.
PD Product Door Not in Place
A product door is not in place or is loose.
The SYSTEM INFORMATIO N is displayed on three
separate screens. The first screen contains the
control and software version installed in the
machine.
SOFTWARE VERSION
C709 CONTROL UVC3
VERSION 1.07
> Next
Figure 53
Touch the SEL symbol to advance to the next
system information screen containing the software
language version.
Language
V1.11 r 00 English 515
> Next
Figure 54
Touch the SEL symbol to advance to the third
system information screen containing the model bill
of material and machine serial number. Touching the
SEL symbol again will return to the Menu list.
B.O.M. C70927C000
S/N K0000000
> Next
Figure 55
The CURRENT CONDITIONS screen provides the
viscosity readings for the product when the machine
is running, and the hopper and the freezing cylinder
temperatures for the machine.
VISC 0.0
HOPPER 41.0
CYLINDER 41.0
Figure 56
CURRENT CONDITIONS is the only Menu screen
that will return the control panel keys to normal
operation. The Menu keys will not be lit when this
option is selected so all panel touch keys are fully
functional. Exit the CURRENT CONDITIONS screen
and return to the Menu by touching the SEL symbol.