Specifications

8
A40085 SEEG R25AT O/M
DEUTSCH
CHECK
NUMBER
DOUBLE
Max. 15 minutes any stage.
Max. 15 minutes in total.
1
Action
Choose checking mode.
Cooking
Sequence
1 Stage only
2 or 3 Stages
R-23AT
Max. 30 minutes
Max. 30 minutes
Max. 30 minutes any stage.
Max. 60 minutes for two stages.
Max. 90 minutes for three stages.
Max. 30 minutes for three stages.
Step Press Key Display
NOTE:
Magnification factor 1.80 for the double quantity is stored in all memories previously.
Your oven can be programmed for up to 3 cooking stages and has 11 preset microwave power levels.
Microwave power level
that can be used
0-40 %
50-100 %
0-40 %
50-100 %
1
2
X
CHECK
NUMBER
DOUBLE
CHECK
NUMBER
MANUAL OPERATION
Checking the magnification factor
Example : Suppose you want to know the magnification factor for double quantity in memory 1, programmed
1.67.
Choose double quantity.
Choose memory number.
Cancel checking mode.
2
3
4
NOTE:
If the time you set exceeds a maximum time, the display will show "EE 9". Touch STOP/CLEAR key (
)
and enter appropriate time.
This model has 11 power levels. Use correct number pad after touching MICROWAVE POWER SETTING key
(
).
R-25AT
Max. 30 minutes
Max. 15 minutes
Max. 30 minutes any
stage.
Max. 30 minutes in total.
Microwave Power
level
Number keys
100%
90%
9
80%
8
70%
7
60%
6
50%
5
40%
4
30%
3
20%
2
10%
1
0%
0
Cooking time that can be used
SEEG R23AT Eng,P04-12 03.7.29, 4:37 PM8