Specifications

12
A40085 SEEG R25AT O/M
DEUTSCH
X 2
DisplayPress KeyAction
Step
COUNTER RESET
Each number of times can be cleared.
Example : Suppose you want to clear the times of memory 1.
(Total count)
(Times memory 1 used)
INFORMATION WITH FILTER INDICATOR
Clean the air intake filter when the FILTER indicator lights up (See page 14.). The FILTER indicator will light up
when the oven has been operated for about 200 hours in total.
To cancel FILTER indicator touch the START key (
). The oven will start to count the operation time
automatically again when the FILTER indicator is canceled.
1
CHECK
NUMBER
CHECK
NUMBER
CHECK
Choose checking mode.1
Choose the memory 1.
Clear times of using the memory 1.
Cancel checking mode.
2
3
4
CHECK will flash on and off.
INFORMATION WITH ERROR MESSAGES
If ERROR messages are displayed, follow the below instructions.
ERROR MESSAGES
EE1, EE2, EE3,
EE6, E10, EE16
NOTE:
1. To clear times of manual cooking, touch MANUAL/REPEAT key (
) at step 2 instead of NUMBER key.
To clear times of Defrost cooking, touch EXPRESS DEFROST key (
) at step 2 instead of NUMBER
key.
2. To clear total using times, skip step 2.
Please contact your dealer or an authorized Sharp service agent because the oven
must be out of order.
Exhaust air temperature is too high. Checking that nothing is blocking the ventilation
openings or that room temperature is very hot or that oven cavity is empty during
operation. Correct, touch STOP/CLEAR key (
) and try again after a few
minutes.
The time you set exceeds a maximum time. Touch STOP/CLEAR key (
) and
enter appropriate time.
Magnetron temperature is too high, touch STOP/CLEAR key (
) and try again
after a few minutes.
EE7
EE9
EE17
EE19 (For R-25AT )
EE8,EE0 (For R-23AT)
SEEG R23AT Eng,P04-12 03.7.16, 2:55 PM12