Specifications
TDB3108, WF3208 Installation
14 4/30/2013 Bradley • 215-1187 Rev. P; ECN 13-00-001
4b
Adaptive Infrared Assembly for B Drain and H Drain Units with
Tie Pipe Option continued...
D
Place the infrared module assembly on top of
sprayhead. Rotate until infrared module locks in
with tie bar. Drop two infrared module wires down
to valve assembly.
Skip to step F for units without soap.
E
For units with soap option, slide the spacer and
soap dispenser over the 1-1/2" pipe.
F
Position the upper tie bar slightly below the module
or soap dispenser and fasten securely to vent pipe
with set screws provided. Secure top cover to tie
bar with two cap screws provided.
G
For B Unit: Install 1/2" nominal copper tubing
supply lines (pass them through holes in cover
down through support column) and connect supply
lines to stops using suitable fittings.
Unit with "B" Drain and I.R. Module
Shown, Also Available with "H" Drain
Top
Cover
Soap
Dispenser
Spacer
Module
Cover
Infrared Module
Assembly (S50-344)
Tie Bar
Sprayhead
(S05-054)
Support Tube
Std. (S57-005)
Juv. (S57-006)