Specifications
Installation TDB3108, WF3208
Bradley • 215-1187 Rev. P; ECN 13-00-001 4/30/2013 7
(mm)
Rough-In Specifications
Type H
Centrally rising vent
with supplies from
below
7-5/8"
(194)
2-1/2"
(64)
1" NPT Supplies Through
Floor: Stub Up 2-1/2" (64)
Above Floor
Cold
Hot
4"
(102)
2" NPT Drain,
Stub Up 3" (76)
Above Floor
4"
(102)
Suggested
Electrical Outlet
Location
54" (1372) Bowl
1-1/2" NPT
Vent to Ceiling
7-5/8"
(194)
Supply lines for one to two
washfountains should be 1"; for
three washfountains, 1-1/4". For
more than three washfountains,
pipe sizes should be increased
proportionately.
Type O
Off-line vent with
supplies from above
1" NPT Supplies From Above Must
Reduce to 1/2" Nom. Copper Tube on
These Centers to Pass Thru Washfountain
7/8" (22)
7/8" (22)
Cold
Hot
1-1/4"
(32)
Suggested
Electrical Outlet
Location
4" (102)
2" NPT Drain,
Stub Up 3" (76)
Above Floor
54" (1372) Bowl
4"
(102)
Supply lines for one to two
washfountains should be 1"; for
three washfountains, 1-1/4". For
more than three washfountains,
pipe sizes should be increased
proportionately.