Service manual

27
R-300BW
6
45
1
2
3
6
45
1
2
3
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Figure S-1. Pictorial Diagram
HIGH VOLTAGE
CAPACITOR
H.V.
RECTIFIER
POWER SUPPLY 
CORD 120V 60Hz
HIGH VOLTAGE COMPONENTS
GRN
OVEN LAMP 
AND SOCKET
MAGNETRON
COM.
MONITOR
SWITCH
COM.
N.O.
N.C.
DOOR
SENSING
SWITCH
SECONDARY
INTERLOCK
SWITCH
TURNTABLE
MOTOR
NOTE:
Hot (YLW) wire must be
connected to the terminal
with blue mark on the
oven light socket.
H
N
POWER 
TRANSFORMER
COM.
NO
NOTE:
The grounding conductor of
the power supply cord has
been grounded by power
supply cord fixing screw.
The screw must allways be
kept tight.
NOTE:
The neutral (WHT) wire must be
connected to the terminal with "N"
mark on the power supply cord.
BLK
GRY
RED
WHT
BLK
WHT
BLK
BLK
GRY
GRN
GRN
R
E
D
WHT
GRY
BLK
BLK
WHT
BLUE MARK
BLKBLK
OVEN
THERMAL CUT-OUT
WHT
WHT
FAN MOTOR
THERMAL CUT-OUT (MG.)
FUSE
&
HOLDER
BLK
BLK
BLK
BLK
GRY
WHT
WHT
WHT
GRY
BLK
ORG
RED
CONTROL UNIT
SP1
CN-A
CN-B
RY2
T1
RED
ORG
WHT
BLK
CN-B
CN-A
4
GRN
GRY
5
1
2
3
2
1
GRN