User Manual
Table Of Contents
- PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
- WARNING TO SERVICE PERSONNEL
- MICROWAVE MEASUREMENT PROCEDURE
- FOREWORD AND WARNING
- PRODUCT DESCRIPTION
- GENERAL INFORMATION
- OPERATION
- TROUBLESHOOTING GUIDE
- TEST PROCEDURES
- [1] Procedure A: MAGNETRON ASSEMBLY TEST
- [2] Procedure B: POWER TRANSFORMER TEST
- [3] Procedure C: HIGH VOLTAGE RECTIFIER TEST
- [4] Procedure D: HIGH VOLTAGE CAPACITOR TEST
- [5] Procedure E: THERMAL CUT OUT TEST
- [6] Procedure F: SECONDARY INTERLOCK SWITCH TEST
- [7] Procedure F: PRIMARY INTERLOCK SYSTEM TEST
- [8] Procedure G: MONITOR SWITCH TEST
- [9] Procedure H: BLOWN MINITOR FUSE TEST
- [10] Procedure I: NOISE FILTER TEST
- [11] Procedure J: CONTROL PANEL ASSEMBLY TEST
- [12] Procedure L: RELAY TEST
- [13] Procedure M: FOIL PATTERN ON THE PRINTED WIRING BOARD TEST
- TOUCH CONTROL PANEL ASSEMBLY
- PRECAUTIONS FOR USING LEAD-FREE SOLDER
- COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
- [1] WARNING
- [2] OUTER CASE REMOVAL
- [3] POWER TRANSFORMER REMOVAL
- [4] HIGH VOLTAGE RECTIFIER ASSEMBLY AND HIGH VOLTAGE CAPACITOR REMOVAL
- [5] MAGNETRON REMOVAL
- [6] CONTROL PANEL ASSEMBLY REMOVAL
- [7] OVEN LAMP AND LAMP SOCKET REMOVAL
- [8] POSITIVE LOCK CONNECTOR (NO-CASE TYPE) REMOVAL
- [9] ANTENNA MOTOR REMOVAL
- [10] COOLING FAN MOTOR REMOVAL
- [11] POWER SUPPLY CORD REPLACEMENT
- [12] DOOR SENSING SWITCH/SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH REMOVAL
- [13] DOOR SENSING SWITCH/SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH ADJUSTMENT
- [14] DOOR PARTS REMOVAL
- [15] ANTENNA MOTOR SHAFT REPLACEMENT
- [16] INSTALLATION OF CERAMIC SHELF
- CIRCUIT DIAGRAMS
- Parts List
R21LCF
8 – 3
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
[7] Procedure F: PRIMARY INTERLOCK SYSTEM TEST
1. DOOR SENSING SWITCH
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an
open circuit with the door open and a closed circuit with the door closed. If improper operation is indicated, replace the door sensing switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
NOTE: If the door sensing switch contacts fail in the open position and the door is closed, the cooling fan, antenna and oven light will be activated by
RY1.
2. PRIMARY INTERLOCK RELAY (RY1)
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect two (2) wire leads from the male tab terminals of the Primary Interlock Relay. Check the state of the relay contacts using a ohmmeter.
The relay contacts should be open. If the relay contacts are closed, replace the circuit board entirely or the relay itself.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
[8] Procedure G: MONITOR SWITCH TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Before performing this test, make sure that the secondary interlock switch and the primary interlock relay are operating properly, according to the
above Switch Test Procedure. Disconnect the wire lead from the monitor switch (COM) terminal. Check the monitor switch operation by using the
ohmmeter as follows. When the door is open, the meter should indicate a closed circuit. When the monitor switch actuator is pushed by a screw
driver through the lower latch hole on the front plate of the oven cavity with the door opened (in this condition the plunger of the monitor switch is
pushed in), the meter should indicate an open circuit. If improper operation is indicated, the switch may be defective. After testing the monitor
switch, reconnect the wire lead to the monitor switch (COM) terminal and check the continuity of the monitor circuit.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
[9] Procedure H: BLOWN MINITOR FUSE TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
SCREW
DRIVER
MONITOR
SWITCH
OHMMETER
WHT/ WHT