Technical data

13773-001
34-40
Page 2 31 July 2001
(2) Installation - Garmin GNS 430 GPS/COM
CAUTION: When mounting the transceiver, do not press on display window as damage may
result.
(a) With light to medium pressure, push transceiver into mounting tray to engage electrical
connectors.
(b) Insert hex wrench into front panel bolt hole and engage hex bolt.
(c) Turn bolt clockwise to tighten locking cam.
(d) Reset ESSENTIAL and NON-ESSENTIAL AVIONICS circuit breakers.
(3) Inspection/Check VHF COM Check - GNS 430
A flight test is recommended after the installation to ensure satisfactory performance. To check
the communications transceiver, maintain an appropriate altitude and contact a ground station
facility at a range of at least 50 nautical miles. Contact a close ground station. Press the squelch
disable button to defeat the automatic squelch feature and listen for any unusual electrical noise
which would increase the squelch threshold. If possible, verify the communications capability on
both the high and low ends to the VHF COM band.
B. Multifunction Display (MFD) (See Figure 34-401)
(1) Removal - Multifunction Display (MFD)
(a) Ensure BAT 1, BAT 2, and AVIONICS master switches are in off position.
(b) Pull MFD circuit breaker.
(c) Rotate captive screws counterclockwise to loosen MFD from instrument panel.
CAUTION: When removing MFD, do not strain wire harness by pulling cable too far
from instrument panel.
(d) Pull MFD from instrument panel just sufficiently to expose cable connector.
(e) Rotate cable plug counterclockwise and remove from receptacle.
(f) Remove MFD from airplane.
(2) Installation - Multifunction Display (MFD)
(a) Position MFD close enough to instrument panel cutout to connect cable plug to receptacle
without straining wire harness.
(b) Insert MFD into instrument panel cutout and slide forward until captive screws align with
instrument panel mounting holes.
(c) Rotate captive screws clockwise until detent position is felt indicating screw is aligned with
receptacle. Continue clockwise rotation approximately 1/4 turn until screw is secure.
(d) Reset MFD circuit breaker.