Specifications

SPEC No.
LC99213A
MODEL No.
LM10V332
PAGE
20
5-2) Operating life
The operating life time is 25 000 hours or more at 5.5 mA , at 25.
(Operating life with CXA-M10L or equivalent.)
The inverter should meet the following conditions to keep the specified life time of used lamp;
Since, symmetric waveform without spike in positive and negative
Output frequency range : 30 kHz-70 kHz
Make sure the operating conditions by executing the burn-in enough time.
The operating life time is defined as having ended when any of the following conditions occur;
25± 1
When the voltage required for initial discharge has reached 110 % of the initials value.
When the illuminence quantity of light has decreased to 50 % of the initials value.
(NOTE) Rating are defined as the average brightness inside the viewing area specified in Fig.10.
ACTIVE AREA
120
240
360
dot
160 320 480 dot
Fig.10 Measuring points (①-⑤)