Specifications
SPEC No.
LC99213A
MODEL No.
LM10V332
PAGE
23
1.
Operator
Electrostatic shielding clothes shall be had because it is feared that the static electricity is
electrified to human body in case that operator have a insulating garment.
2.
Equipment
There is a possibility that the static electricity is charged to equipment which have a function of
peeling or mechanism of friction(EX: Conveyer, soldering iron, working table), so the
countermeasure (electrostatic earth:1×10
8
Ω) should be made.
3.
Floor
Floor is a important part to leak static electricity which is generated from human body or
equipment.There is a possibility that the static electricity is charged to them without leakage
in case of insulating floor,so the countermeasure(electrostatic earth:1×10
8
Ω) should be made.
4.
Humidity
Humidity of working room may lower electrostatics generating material’s resistance and have
something to prevent electrifying. So, humidity should be kept over 50% because humidity less
than 50 % may
increase material’s electrostatic earth resistance and it become easy to electrify.
5.
Transportation/storage
The measure should be made for storage materials because there is a possibility that the static
electricity,which electrify to human body or storage materials like container by friction or
peeling,cause the dielectric charge.
6.
Others
The laminator is attached on the surface of LCD module to prevent from scratches, fouling and
dust. It should be peeled off unhurriedly with using static eliminator.
And also, static eliminator should be installed to prevent LCD module from electrifying at
assembling line.
8)
Don’t use any materials which emit gas from epoxy resin(amines’ hardener) and silicon
adhesive agent(dealcohol or deoxym) to prevent change polarizer color owing to gas.
9)
Since leakage current, which may be caused by routing of CCFT cables, etc., may affect the
brightness of display, the inverter has to be designed taking the leakage current into
consideration. Thorough evaluation of the LCD module/inverter built into its host equipment
shall be conducted, therefore, to ensure the specified brightness.
10)
Avoid to expose the module to the direct sun-light, strong ultraviolet light, etc. for a long time.
11)
If stored at temperatures under specified storage temperature, the LC may freeze and be
deteriorated. If storage temperature exceed the specified rating, the molecular orientation of
the LC may change to that of a liquid, and they may not revert to their original state. Therefore,
the module should be always stored at normal room temperature.
12)
Disassembling the LCD module can cause permanent damage and should be strictly avoided.