Product manual

Welding equipment
Installation
Installation_eng.fm 21
4 Installation
4.1 Configuration of Welding Equipment
4.1.1 Flexible Interface/ ARCITEC (LRB/LRC)
On delivery the equipment is configured according to applicable configuration data
which are stored on the disk that comes with the delivery. The data can be read and
modified by way of the robot programming unit. See chapter 6.5.
For the definition of configuration data, see “Appendix 1” on page 57.
The following files on the installation disk contain configuration data for the weld-
ing equipment:
Rpa_Fhp.cfg Explanation: Configuration data for power source RPA and
wire feed unit A140E/A314E/A324E-L_PIB
Law_Fhp.cfg Explanation: Configuration data for power source LAW and
wire feed unit A140E/A314E/A324E-L_PIB
Lrb_Fhp.cfg Explanation: Configuration data for power source LRB/LRC
and wire feed unit A140E/A314E/A324E-L_PIB
Laf_Fhp.cfg Explanation: Configuration data for power source LAF and
wire feed unit Welding equipment_PIB
In case these configuration data must be reloaded, proceed in one of the following
ways:
Roboot the robot: The original configuration will be restored.
Manual loading using the programming unit: Print out the configuration
data from the disk supplied. This can be done using an ordinary PC and a
word processing program (for example Notepad in Windows). If required,
the configuration data can now be adjusted according to the printout by way
of the programming unit.
Loading from the configuration disk: Executed by way of the robot
instruction System Parameters\IO Signals\File "Add or Replace
Parameters\ "file"
Important!
As the disk is unique for the equipment supplied it should be stored in a safe place.
The program number indicated on the disk corresponds to the configuration in
question, and should be referred to in case of service matters regarding the function
of the welding equipment.